CARE AND MAINTENANCE
Air freshening filter
P
L
ASMA
¾²
µç
¼¯
³¾
Æ÷
ÂË
Íø
ÔÚ
´ò
¿ª
Ãæ
°å
10
·Ö
Ö®
ÄÚ
£¬
Çë
Îð
´¥
Ãþ
P
LASMA
¼¯
³¾
Æ÷
£¬
ÒÔ
Ãâ
´¥
µç
¡£
ÓÃ
ÊÖ
ÎÕ
ס
P
LASMA
¾²
µç
¼¯
³¾
Æ÷
µÄ
Á½
¸ö
±ê
ÓÐ
Ïò
ÉÏ
¼ý
Í·
µÄ
²¿
λ
£¬
ÓÃ
ÊÖ
Ö¸
ÓÃ
Á¦
Íù
ÉÏ
̧
Æð
£¬
¿Û
λ
ËÉ
¿ª
£¬
¿É
ÒÔ
´ò
¿ª
¾²
µç
¼¯
³¾
Æ÷
£¬
È¡
³ö
ÂË
Íø
¡£
1
2
Plasma
Air filter
Hold the two parts of Plasma where are
marked with signal and lift it. Then you
can open the cover of the the plasma and
remove the filter.
4. Remove the Air Freshening Filters from its supporting
frame (The solution to disassemble may differ from
each other for different filters. Refer to and ).
Clean the air freshening filter at least once a month,
and replace it every 4-5 months.
Clean it with vacuum cleaner, then dry it in cool place.
For the models with plasma, do not touch the plasma
within 10 minutes after you open the panel.
5. Install the air freshening filter back into position.
6. Insert the upper portion of air filter back into the
unit, taking care that the left and right edges line up
correctly and place filter into position.
1
2
Preparation for extended non-operation
Pre-season inspection
If you plan to idle the unit for a long time, perform
the following:
(1) Clean the indoor unit and filters.
(2) Operate the fan for about half a day to dry the
inside of the unit.
(3) Stop the air conditioner and disconnect power.
(4) Remove the batteries from the remote controller.
The outdoor unit requires periodic maintenance
and cleaning. Do not attempt to do this yourself.
Contact your dealer or service provider.
Check that the wiring is not broken off or disconnected.
Clean the indoor unit and filters.
Check that the air filter is installed.
Check if the air outlet or inlet is blocked after the
air conditioner has not been used for a long time.
Do not touch the metal parts of the unit when
removing the filter. Injuries can occur when
handling sharp metal edges.
Do not use water to clean inside the air conditioner.
Exposure to water can destroy the insulation,
leading to possible electric shock.
When cleaning the unit, first make sure that the
power and circuit breaker are turned off.
Do not wash air filter with hot water at more than
O
40 C . Shake off moisture completely and dry
it in the shade. Do not expose it directly to the sun,
it may shrink.
O
/104 F
Caution
Replacement of air filter and air freshening filter
1. Remove the air filter.
2. Remove the air freshening filter.
3. Install a new air freshening filter.
4. Reinstall the air filter and securely close the front
panel.
The following events may occur during normal operation.
1. Protection of the air conditioner.
Compressor protection
The compressor can't restart for 3-4 minutes after it stops.
Anti-cold air (Cooling and heating models only)
The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in
one of the following three situations and the set temperature has not been reached.
A) When heating has just started.
B) Defrosting.
C) Low temperature heating.
The indoor or outdoor fan stop running when defrosting (Cooling and heating models only).
Defrosting (Cooling and heating models only)
Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low
and humidity is high resulting in lower heating efficiency of the air conditioner.
During this condition air conditioner will stop heating operation and start defrosting automatically.
The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and
the amount of frost built up on the outdoor unit.
2. A white mist coming out from the indoor unit
A white mist may generate due to a large temperature difference between air inlet and air outlet
on COOL mode in an indoor environment that has a high relative humidity.
A white mist may generate due to moisture generated from defrosting process when the air
conditioner restarts in HEAT mode operation after defrosting.
3. Low noise of the air conditioner
You may hear a low hissing sound when the compressor is running or has just stopped running.
It is the sound of the refrigerant flowing or coming to a stop.
You can also hear a low "squeak" sound when the compressor is running or has just stopped
running. This is caused by heat expansion and cold contraction of the plastic parts in the unit
when the temperature is changing.
A noise may be heard due to louver restoring to its original position when power is turned on.
4. Dust is blown out from the indoor unit.
This is a normal condition when the air conditioner has not been used for a long time or during first
use of the unit.
5. A peculiar smell comes out from the indoor unit.
This is caused by the indoor unit giving off smells permeated from building material, from furniture,
or smoke.
6. The air conditioner turns to FAN only mode from COOL or HEAT (For cooling and
heating models only) mode.
When indoor temperature reaches the temperature setting on air conditioner, the compressor will
stop automatically, and the air conditioner turns to FAN only mode. The compressor will start again
when the indoor temperature rises on COOL mode or falls on HEAT mode (For cooling and heating
models only) to the set point.
Normal function of the air conditioner
TROUBLESHOOTING TIPS
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Midea OASIS MSOH at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Midea OASIS MSOH in the language / languages: English as an attachment in your email.

The manual is 2,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Midea OASIS MSOH

Midea OASIS MSOH Installation Guide - English - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info