588137
14
Zoom out
Zoom in
Previous page
1/19
Next page
NOTE:
For some models, the indoor unit is especially designed to used as either MULTI models
or MONO models. If your air conditioner is not set to the MULTI position, see the following
INDOOR WIRING DIAGRAM to modify the indoor unit from MONO model to MULTI model.
(Fig.25 & 26)
1. Carefully remove the front panel and frame, then remove the Electricall control cover
by loosen the screw.
2. Remove the POWER SUPPLY cord of MONO model(Fig.25).
3. Unplug the then connect it
with
“L” RED wire connected with “4” on pinboard of RY1,
“3” on pinboard of Ry1.
4. Reinstall the Electrical Control cover and screw, rip off the white paper above the
Slide Switch and move it to the MULTI position(see Fig. 25).
5. Reinstall the front panel and frame.
6. Now the indoor unit can be used as MULTI models(Fig.26). Because the control
system is changed, the AUTO CLEAN function is unavailable for MULTI models.
INDOOR FAN MOTOR
LOUVER MOTOR
N
CN1
CN3
CN6
CN7
CN8
CN2
CN17
CN9
5
7
L
N
S
L
Y/G
BLACK
RED
S
L
N
WHITE
RED
CN14
CN11
OUTDOOR UNIT
INDOOR PCB
2
4
S
YELLOW
TRANSFORMER
JX1
INDOOR WIRING DIAGRAMINDOOR WIRING DIAGRAM
ROOM TEMP. SENSOR
PIPE TEMP. SENSOR
CN4
AUTO RESTART
CN15
IONIZER
SWITCH BOARD
DISPLAY BOARD
5
5
CN12
CN13
3
3
2
2
3
3
RY1
3
4
CN5
2
PLUMB STEP MOTOR
DOOR STEP MOTOR
2205209008
INDOOR FAN MOTOR
LOUVER MOTOR
N
CN1
CN3
CN6
CN7
CN8
CN2
CN17
CN9
5
7
BROWN
BLUE
L
N
S
L
Y/G
BLACK
RED
S
L
N
WHITE
RED
CN14
CN11
OUTDOOR UNIT
INDOOR PCB
POWER SUPPLY
2
4
S
YELLOW
TRANSFORMER
JX1
Y/G
INDOOR WIRING DIAGRAMINDOOR WIRING DIAGRAM
ROOM TEMP. SENSOR
PIPE TEMP. SENSOR
CN4
AUTO RESTART
CN15
IONIZER
SWITCH BOARD
DISPLAY BOARD
5
5
CN12
CN13
3
3
2
2
3
3
RY1
3
4
CN5
2
PLUMB STEP MOTOR
DOOR STEP MOTOR
MONO MODELS
MULTI MODELS
MONO
MONO
MULTI
Rip off the
white paper
MONO
MONO
MULTI
Fig.25
Fig.26
ELECTRICAL WORK
13
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Midea MSXI-12HRDN1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Midea MSXI-12HRDN1 in the language / languages: English as an attachment in your email.

The manual is 0,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Midea MSXI-12HRDN1

Midea MSXI-12HRDN1 User Manual - English - 14 pages

Midea MSXI-12HRDN1 User Manual - Dutch - 10 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info