Drillaholeinthewall(suitablejustforthesizeofthewallconduit,53,71seriesdiameteris90mm,
and120,105,140seriesdiameteris105ingeneral),thensetonthefittingssuchasthewall
conduitanditscover.
Bindtheconnectingpipeandthecablestogethertightlywithbindingtapes.Donotletairin,which
willcausewaterleakagebycondensation.
Passtheboundconnectingpipethroughthewallconduitfromoutside.Becarefulofthepipealloc-
ationtodonodamagetothetubing.
2.LocateThePipes
3.Connectthepipes.
4.Then,openthestemofstopvaluesoftheoutdoorunittomaketherefrigerantpipeconnec-
tingtheindoorunitwiththeoutdoorunitinfluentflow.
5.Besureofnoleakagebycheckingitwithleakdetectororsoapwater.
6.Coverthejointoftheconnectingpipetotheindoorunitwiththesoundproof/insulating
sheath(fittings),andbinditwellwiththetapestopreventleakage.
Ф
Ф
Usethemarketbrasspipe
Besuretousethesameinsulatingmaterialswhenyoubuythebrasspipe(morethan9mmthick).
Flaring
90
Leancrudeburr
Chart 22 Chart23
1.Cutapipewithapipecutter.
2.Insertaflarenutintoapipeandflare
thepipe.
Fastenthenuts
Puttheconnectingtubingattheproperposition,
wrenchthenutswithhands,thenfastenitwitha
wrench.(RefertoChart24)
CAUTIONS
Toolargetorquewillharmthebellmouthing
andtoosmallwillcauseleakage.Please
determinethetorqueaccordingtoTable2.
10
Chart24
Capacity
LENGTH(L)
Lessthan8m(one-way)
AddedRefrigerantWhenOver8m(one-way)
Table3
Pleaserecordandreservewelltherefrigerantstowcapacityofyourairconditionerforlatermaintenance.
NecessaryRefrigerantStowCapacity
65g(L-8)m×
A(mm)
Max Min
6.35
8.3
9.53
12.4
12.7
15.8
16
19.0
19
23.3
Outside-diameter
(mm)
8.3
12.0
15.4
18.6
22.9
(kg)
6.35φ
1420~1720Ncm
.
(144~176kgfcm)
.
φ9.53
3270~3990Ncm
.
(333~407kgfcm)
.
φ12.7
4950~6030Ncm
.
(504~616kgfcm)
.
φ166
6180~7540Ncm
.
(630~770kgfcm)
.
φ199
9720~11860Ncm
.
(990~1210kgfcm)
.
TubingSize Torque
Table2
18000-24000Btu/h
30000-48000Btu/h
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Midea MOU18HN1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Midea MOU18HN1 in the language / languages: English as an attachment in your email.

The manual is 1,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Midea MOU18HN1

Midea MOU18HN1 User Manual - English - 22 pages

Midea MOU18HN1 User Manual - Dutch - 10 pages

Midea MOU18HN1 Installation Guide - Dutch - 9 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info