588101
32
Zoom out
Zoom in
Previous page
1/39
Next page
31
ELECTRICAL WORK
Fig.61
Connect the cable to the outdoor unit
1. Remove the electrical control board cover
from the outdoor unit by loosening the screw
as shown in Fig.61
2. Connect the connective cables to the
terminals as identified with their respective
matched numbers on the terminal block of
indoor and outdoor units.
3. Secure the cable onto the control board with
the cord clamp.
4. To prevent the ingress of water, from a loop
of the connective cable as illustrated in the
installation diagram of indoor and outdoor
units.
5. Insulate unused cords (conductors) with
PVC-tape.Process them so they do not
touch any electrical or metal parts.
Wiring connection
NOTE: Before performing any electrical
work, turn off the main power to the system.
Connection Cable
10mm
40mm
CAUTIONS
Do not touch the capacitor even if you
have disconnected the power for there is
still high voltage power on it, or electric
shock hazard may occur. For your safety,
you should start repairing at least 5 minutes
later after the power is disconnected.
The power is supplied from the Outdoor
Unit. The Indoor Units are connected
with signal wires or power cords are
connected reliably and correctly, or the
air conditioner could not run normally.
Fig.62
CAUTIONS
Make sure to connect the indoor unit (A,B, C, D,
E) to the Hi and Lo valve and terminals of signal
wires(A, B, C, D, E) of outdoor unit as identified
with their respective matched connection.
Wrong wiring connections may cause some
electrical parts to malfunction.
Minimum norminal cross-sectional area
of conductors:
Rated current of appliance
(A)
Nominal cross-sectional
2
area (mm )
>3 and <6
>6 and <10
>10 and <16
>16 and <25
0.75
1
1.5
2.5
Screw
Cover
Connective cable
of indoor unit and
outdoor unit
Connective cable
of indoor unit and
outdoor unit
Connective cable
of indoor unit and
outdoor unit
Connective cable
of indoor unit and
outdoor unit
Connective cable
of indoor unit and
outdoor unit
One-two One-three One-four
One-five
POWER
E
E
Suggest Minimum Wire Size
(AWG: ):American Wire Gage
Appliance Amps
AWG Wire Size
10
13
18
25
18
16
14
12
30
10
The cable size and the current of thefuse or
switch are determined by the maximum current
indicated on the nameplate which located on the
side panel of the unit. Please refer to the
nameplate before selecting the cable, fuse and
switch. Please refering to the above tables and
choosing the proper wire size under the local
electrical requirements.
NOTE:
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Midea 4M-105K at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Midea 4M-105K in the language / languages: English as an attachment in your email.

The manual is 10,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Midea 4M-105K

Midea 4M-105K User Manual - English - 33 pages

Midea 4M-105K Installation Guide - German - 39 pages

Midea 4M-105K User Manual - German - 33 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info