INSTALLATION INSTRUCTIONS
3. Duct & Ceiling type
Installation precautions
1. Determine the moving route.
2. Move the unit in original state.
3. Make sure to do electric insulation according to relevant electric standard
in case the unit is installed on metal part of building.
Indoor unit installation
Refrigerant
pipe
Air outlet
Air return box
Direction A
<500mm
Duct
>100mm
>200mm
>250mm
<3m
<1000mm
4. Please keep away from the following places, or malfunction may be caused.
(if unavoidable, please consult the professionals):
A. There is mineral oil like the oil of cutting machine.
B. There is much salty air. (Near the coast)
C. There is caustic gas such as sulfuric gas. (Near the hotspring.)
D. Factory where the voltage fluctuate greatly.
E. In the car or in the cabin.
F. In the kitchen or a place full of oil steam..
G. There is strong electromagnetic wave.
H. There is combustible gas or materials.
I. There is much evaporating acid or alkaline gas.
J. Other special areas.
Enough room for installation and maintenance.
The ceiling is horizontal and it can afford the weight of the indoor unit.
The air inlet and outlet are not impeded and does not affected by outdoor air too much.
The air flow can reach every part of the room.
The connecting pipe and drainpipe can be easily extracted out.
There is no direct radiation from heat source.
Installation location
Air return box
Air return box
Air outlet
<500mm
Direction A
Function
Insulation pipe
Remote controller
Big washer
Constriction bandage
Water outlet joint (for cool/heat type only)
Name
Qty.NO
Outline
1
2
3
4
5
6
7
8
2
1
8
Pipe joint heat insulation
Overhang indoor unit
Binding insulation pipe
Remote control air conditioner
9
10
Gasket (for cool/heat type only)
Copper nut
10
1
1
2
Connecting pipe
Outdoor unit drainage
Drain hose
1
Indoor unit drainage
Outdoor unit drainage
7# Alkaline battery
Remote signal receiver subassembly
1
1
Accessories
Magnetic ring
11
1
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Midea 4M-105K at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Midea 4M-105K in the language / languages: English as an attachment in your email.

The manual is 10,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Midea 4M-105K

Midea 4M-105K User Manual - English - 33 pages

Midea 4M-105K Installation Guide - German - 39 pages

Midea 4M-105K User Manual - German - 33 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info