VeniceU
Operator Manual
Appendix E: Best Grounding Practice
This appendix gives details of the best grounding practices for the VeniceU console in
order to get the optimum performance out of it.
Safety first
The VeniceU is classified as a class 1 device and as such there is a safety
requirement for the power cable to provide an earth connection to the console.
This connection is bonded to all external metal parts such that in the event of
a failure within the AC power systems it is impossible for any external parts of
the product to become live. When connecting other equipment to the VeniceF
to form an audio system, it is likely that some of these additional devices will
also be class 1, so they will require a safety earth too. For your own safety,
the safety of others and to comply with the law, it is important that none of
these earth connections are tampered with in any way.
Ground loops
When connecting audio signals or data between devices within an audio system, a
signal ground connection must be provided that screens the signals from
electromagnetic interference. This ground connection, combined with the safety earth,
produces a ring of conductors often referred to as a “ground loop”. Typically, this gives
rise to induced currents within the components of the loop, namely the ground
conductors, the chassis of the equipment and the safety earth conductors. This is not
dangerous, but if the grounds are used as a reference for audio signals, as occurs with
unbalanced connections, the ground currents may generate small voltages that corrupt
the signal integrity. The audible results are noise added to the intended signal.
Typically, this sounds like hum (from the power AC voltage), buzzing or whistles (from
power supply diodes or switch mode power supplies), or digital noise (from computers).
107


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Midas VeniceU U24 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Midas VeniceU U24 in the language / languages: English as an attachment in your email.

The manual is 5,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info