18 Chapter 6: Operation
DL471 DSP
Operator Manual
Error messages
During operation the following messages will appear on the second line of the LCD
screen display to inform you of a communication problem between the unit and the
control centre’s master controller. When either message is displayed, the unit’s outputs
are muted and the unit has no functionality.
After the unit detects the lack of communication with the master controller, it waits for
a user-configurable period of time (set on the control centre’s GUI) before displaying
the message. This allows the user to choose to have control over the audio for longer
before it is muted.
To rectify the fault, first check that all of the Ethernet connections are good, especially
those on the routers, and make sure that the control centre’s power supply is switched
on. If everything seems ok it is probable that the DL471 DSP unit is faulty. Replace it
with a good one.
waiting for client
The “waiting for client” message scrolls across the screen to
inform you that the unit has not received control data from
the master controller at any time.
UDP timeout
The “UDP watchdog” message means that the unit has
previously received control data from the master controller,
but is no longer receiving it.
DSP unit role allocation
Each DL471 DSP unit has a role within the system, which is allocated as follows:
Unit role number Role
AMU11 Input channels 1 to 24 and effects 1 and 2.
AMU12 Input channels 25 to 48 and effects 3 and 4.
AMU13 Input channels 49 to 72 and effects 5 and 6.
AMU14 Input channels 73 to 96 and effects 7 and 8.
AMU15 Auxes 1 to 16 and effects 9 and 10.
AMU16 Auxes 17 to 32 and effects 11 and 12.
AMU17 Matrix channels 1 to 12 and effects 13 and 14.
AMU18 Matrix channels 13 to 16, masters, solo, monitors,
returns and effects 15 and 16.
AMU19 GEQs 1 to 16.
AMU20 Spare — for N+1 redundancy.
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Midas DL471 DSP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Midas DL471 DSP in the language / languages: English as an attachment in your email.

The manual is 4,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info