40 Appendix D: Setting Up An XL8 System
DL461 Router
Operator Manual
>> To connect the routers to the Stage rack 3 units
Mic splitters: In AES50 audio - bank 1 on the X router, connect sockets 3 and 4
to the AES50 audio - A X sockets on the mic splitters. Repeat for the Y router,
using the mic splitters’ Y sockets.
Line I/O unit: In AES50 audio - bank 1 on the X router, connect socket 6 to the
AES50 audio X socket on the line I/O unit. Repeat for the Y router, using the
line I/O units’ equivalent Y socket.
>> To connect the XL8 to the line I/O units (FOH rack)
Connect the AES50 audio X sockets on the rear of the XL8 Control Centre to the
AES50 audio X socket on both of the line I/O units in the FOH rack. Repeat for the Y
sockets.
>> To connect the XL8 to the RAPIDE
Connect one of the eight ETHERNET (EtherCon® XLR) sockets on the rear of the
RAPIDE unit to the Ethernet control 1 socket of the active network (X or Y) on the
rear of the XL8 Control Centre (see “XL8 system interconnections” on page 42).
>> To daisy chain the DSP units
Important Note:
Do not connect a cable to like numbered sockets, that is, “0” to “0” or “1” to
“1”, as the DSPs will not work; socket numbers are printed to the right of each
socket.
There are two default configurations available, depending on the lengths of the
interconnecting DSP cables supplied, that is, 0.25 m cables or 0.5 m cables. Both
options contain a long cable for connecting the top and bottom units, and the 0.25 m
option has an additional long cable for connecting units AMU 2 and AMU 9.
A cable’s length (cm) can be determined from a three-digit number contained
within its part number (printed on a label attached to the cable). For example, in
a part number of “14150-EZBB-050-0LC 060425TD” the “-050-” indicates a
length of 50 cm.
Connect the DSPs together as shown in the following diagram, according to the cables
supplied with your system. (In the diagram, the cables are coloured and the sockets
numbered to help distinguish them.)
54


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Midas DL461 Router at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Midas DL461 Router in the language / languages: English as an attachment in your email.

The manual is 6,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info