1. The Advantages of this Thermometer
Measurement in 1 second
The innovative infrared technology allows measurement of ear
temperature in only 1 second.
Correct position indication
ACCUsens guidance system confirms the right position in the ear
with «good» displayed on the LCD display and a beep.
Multiple uses (wide range of measurement)
This thermometer offers a wide range of measurement from 0.1-
99.9 °C / 32.2-211.8 °F, meaning the unit can be used to measure
body temperature or it also has a feature allowing it to be used to
measure surface temperature of the following examples:
Milk surface temperature in a baby's bottle
Surface temperature of a baby's bath
Ambient temperature
Probe cover
This thermometer is user-friendly and more hygienic with the
usage of a probe cover.
Probe LED
This thermometer includes a probe LED light which enables the
user to find the correct ear position in the dark.
Accurate and reliable
The unique probe assembly construction incorporates an
advanced infrared sensor, ensuring that each measurement is
accurate and reliable.
Gentle and easy to use
The ergonomic design enables simple and easy use of the ther-
mometer.
This thermometer can even be used on a sleeping child without
causing any interruption.
This thermometer is quick, therefore child-friendly.
Multiple readings recall
Users will be able to recall the last
30
readings with a record of both
time and date when entering the recall mode, enabling efficient
tracking of temperature variations.
Safe and hygienic
No risk of broken glass or mercury ingestion.
Completely safe for use on children.
Using a new probe cover each time, ensures this thermometer
is completely hygienic for use by the whole family.
Fever alarm
10 short beeps and a red LCD backlight alert the patient that he/
she may have a temperature equal to or higher than 37.5 °C.
2. Important Safety Instructions
Follow instructions for use. This document provides important
product operation and safety information regarding this device.
Please read this document thoroughly before using the device
and keep for future reference.
This device may only be used for the purposes described in
these instructions. The manufacturer cannot be held liable for
damage caused by incorrect application.
Never immerse this device in water or other liquids. For
cleaning please follow the instructions in the «Cleaning
and Disinfecting» section.
Do not use this device if you think it is damaged or notice
anything unusual.
Never open this device.
Earwax in the ear canal may cause a lower temperature reading.
Therefore it is important to ensure the subject's ear canal is clean.
Only use this thermometer with a new Microlife branded and
undamaged probe cover to prevent cross-infection.
If the measurement result is not consistent with the patient's
finding or unusually low, repeat the measurement every 15
minutes or double check the result by another core body
temperature measurement.
This device comprises sensitive components and must be
treated with caution. Observe the storage and operating condi-
tions described in the «Technical Specifications» section.
Ensure that children do not use this device unsupervised; some
parts are small enough to be swallowed.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Microlife IR 210 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Microlife IR 210 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Turkish, Spanish as an attachment in your email.

The manual is 7.46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info