536871
5
Zoom out
Zoom in
Previous page
1/78
Next page
5IR 120 EN
3. When the «°C» or «°F» icon is flashing, a beep sound is
heard and the thermometer is ready for measuring 8.
4. Straighten the ear canal by pulling the ear up and back
to give a clear view of the eardrum.
For children under 1 year; pull the ear straight back.
For children of 1 year to adult; pull the ear up and back.
Also refer to the short instructions at the front.
5. While gently pulling the ear, insert the probe snugly into
the ear canal (about 1 sec.) and immediately press the
START button 2. Release the button and wait for the
beep sound. This indicates the end of the measurement.
6. Remove the thermometer from the ear canal. The display
shows the measured temperature
9
.
NOTE:
To ensure accurate readings, wait at least 30 sec.
after 3-5 continuous measurements.
Accumulation of ear wax on the probe can result in less
accurate temperature readings or cross infection between
users.
Therefore, it is essential that the probe is clean
before each measurement.
For cleaning, follow the
instructions in the «Cleaning and Disinfecting» section.
After cleaning the measuring sensor
1
with alcohol,
wait 5 minutes before taking the next measurement
, in
order to allow the thermometer to reach its operating refer-
ence temperature.
10 short beeps and a red LCD backlight alert the patient
that he/she may have a temperature equal to or higher
than 37.5 °C.
For an infant, it is best to have the child lying flat with his/
her head sideways so the ear is facing upwards. For an
older child or adult, it is best to stand behind and slightly
to the side of the patient.
Always take the temperature in the same ear, since the
temperature readings may be different from ear to ear.
In the following situations it is recommended that three
temperatures in the same ear be taken and the highest
one taken as the reading:
1. New born infants in the first 100 days.
2. Children under three years of age with a compromised
immune system and for whom the presence or absence
of fever is critical.
3. When the user is learning how to use the thermometer
for the first time until he/she has familiarized himself/
herself with the device and obtains consistent readings.
4. If the measurement is surprisingly low.
6. Changing between Celsius and Fahrenheit
This thermometer can display temperature readings in either
Fahrenheit or Celsius. To switch the display between °C and
°F, simply turn OFF the unit,
press and hold
the START
button
2
for 5 seconds; after 5 seconds, the current
measurement scale
°C
» or «
°F
» icon) will flash on the
display
AL
. Change the measurement scale between °C and
°F by pressing the START button
2
. When the measure-
ment scale has been chosen, wait for 5 seconds and the unit
will automatically enter the «ready for measuring» mode.
7. How to recall 12 readings in Memory Mode
This thermometer can recall the last 12 readings.
Recall mode AM: Press the START button 2 to enter
Recall mode when power is off. The memory icon «M»
will flash.
Reading 1 - the last reading AN: Press and release the
START button 2 to recall the last reading. Display 1
alone with memory icon.
Reading 12 - readings in succession: Press and
release the START button 2 consecutively to recall the
last 12 readings in succession.
Pressing and releasing the START button 2 after the last
12 readings have been recalled will resume the above
sequence from reading 1.
8. Error Messages
Measured temperature too high
AO
:
Displays «
H
» when
measured temperature is higher than 100.0 °C / 212.0 °F.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Microlife IR 120 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Microlife IR 120 in the language / languages: English, German, Dutch, Danish, French, Italian, Swedish, Norwegian, Finnish as an attachment in your email.

The manual is 2,94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info