5. Directions for Use
6. Changing between Celsius and Fahrenheit
This thermometer can display temperature measurements in
either Fahrenheit or Celsius. To switch the display between
°C and °F, simply turn OFF the unit,
press and hold
the
START button
2
for 5 seconds; after 5 seconds, the current
measurement scale («
°C
» or «
°F
» icon) will be flashing on the
display
AL
. Change the measurement scale between °C and
°F by pressing the START button
2
. When the measurement
scale has been chosen, wait for 5 seconds and the unit will
automatically enter the «ready for measuring» mode.
1. Press the ON/OFF button 4. The display 3 is activated
to show all segments for 2 seconds.
2.
The last measurement reading will automatically be
shown on the display for 2 seconds with the «
M
» icon
7
.
3.
When the «
°C
» or «
°F
» icon is flashing, a beep sound is
heard and the thermometer is ready for measurement
8
.
4. Straighten the ear canal by pulling the ear up and back
to give a clear view of the eardrum.
For children under 1 year; pull the ear straight back.
For children of 1 year to adult; pull the ear up and back.
Also refer to the short instructions at the front.
5. While gently pulling the ear, insert the probe snugly into
the ear canal (max. 1 sec.) and immediately press the
START button 2. Release the button and wait for the
beep sound. This is the indication that confirms the end
of measurement.
6. Remove the thermometer from the ear canal. The display
shows the measured temperature 9.
)
NOTE:
To ensure accurate readings, wait at least 30 sec.
after 3-5 continuous measurements.
Accumulation of ear wax on the probe can result in less
accurate temperature readings or cross infection
between users. Therefore, it is essential that the
probe is clean before each measurement. For
cleaning, follow the instructions in the «Cleaning and
Disinfecting» section.
After cleaning the measuring sensor 1 with
alcohol, wait 5 minutes before taking the next
measurement, in order to allow the thermometer to
reach its operating reference temperature.
10 short beeps will sound when the temperature is
higher than 37.5 °C (99.5 °F) in order to alert the patient
that he/she may have fever.
For an infant, it is best to have the child lying flat with
his/her head sideways so the ear is facing upwards. For
an older child or adult, it is best to stand behind and
slightly to the side of the patient.
Always take the temperature in the same ear, since the
temperature readings may be different from ear to ear.
Wait for a few minutes to take the ear temperature after
sleeping.
In the following situations it is recommended that three
temperatures in the same ear be taken and the highest
one taken as the reading:
1. New born infants in the first 100 days.
2. Children under three years of age with a compromised
immune system and for whom the presence or
absence of fever is critical.
3. When the user is learning how to use the thermometer
for the first time until he/she has familiarized himself/
herself with the instrument and obtains consistent
readings.
4. If the measurement is surprisingly low.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Microlife IR 100S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Microlife IR 100S in the language / languages: English, Spanish as an attachment in your email.

The manual is 0,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info