If the wrist artery lies considerably lower (higher) than the heart, an erroneously higher (lower)
blood-pressure will be measured! (Each 15 cm difference in height results in a measurement
error of 10 mmHg!)
A loose cuff causes false measurement values.
5.3. Fitting the cuff
a) Remove all eventual objects and jewellery (e.g. wrist-
watch) from the wrist in question. Draw the cuff over
the wrist.
b) The distance between the cuff and the hand should be
approx. 10 mm.
c) Secure the cuff with the fastener, so that it lies
comfortably and not too tight, whereby no space
should remain between the cuff and the wrist.
d) Lay the arm on a table, with the palm upwards. Support
the arm a little with a rest (cushion), so that the cuff
rests at about the same height as the heart. Take care,
that the cuff lies free.
5.4. Measuring procedure
After the cuff has been appropriately positioned and the
setting of the pressure pre-selection has been undertaken,
the measurement can begin:
a) Press O/I button to put the device into operation
b) Press the START button – the pump begins to inflate the
cuff. In the display, the increasing cuff-pressure is
continually displayed.
c) After reaching the inflation pressure, the pump stops and the pressure
slowly falls away. The cuff-pressure (large characters) is displayed
during the measurement. When the device has detected the pulse, the
heart symbol in the display begins to blink and a peep tone is audible
for every pulse beat.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Microlife BP 3BEO-4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Microlife BP 3BEO-4 in the language / languages: English, French, Spanish as an attachment in your email.

The manual is 0,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info