536851
15
Zoom out
Zoom in
Previous page
1/52
Next page
If the data of each cycle differ too much from each
other, a fourth measurement is performed before
the result is displayed. In rare cases when the
blood pressure is so unstable that even after four
measurements the data vary too much, an error
message is displayed. Refer to Error Messages and
Malfunctions (Section 7) at the end of this manual.
5.6. Discontinuing a measurement
If it is necessary to interrupt a measurement for any reason, for example if the patient feels unwell,
press the O/I button. The device immediately lowers the cuff-pressure and enters into sleep mode.
6. Memory handling and user setting
6.1 Viewing Measurements Saved in Memory
The blood pressure monitor automatically stores each of the
last 30 measurement values. To view the stored measurements
for a user, press or in sleep mode. The last measurement
taken for the user is displayed.
The user, measurement sequence number, date, and time
are displayed on the top. Data obtained in Average Mode are
indicatedby«MAM»intheupperrightcorner.
Press or to scroll through the list items. The first item in
the list is the average of all stored data.
Press OK and the display shows table of all data.
The first entry is the average. Data obtained in Average Mode
areindicatedbyan«A»attheveryright.
Press or to scroll through the list.
13
15
Countdown
timer
Measurement
number
9 MAM
3/03 15:48
sys
124 mmHg
dia
73 mmhg
pul
77 /min.
Measurement
number
3/03 15:48
No. sys dia pul
avg. 149 110 85
1 145 109 83
2 119 71 74 A
3 124 73 79
4 130 80 77 A
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Microlife BP 3AX1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Microlife BP 3AX1 in the language / languages: English as an attachment in your email.

The manual is 0,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Microlife BP 3AX1

Microlife BP 3AX1 User Manual - German, French, Spanish - 82 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info