nal flash unit or an illuminator incorporated in the camera body. The
preflash function is set on the camera (see the camera’s operating
instructions)! Second curtain synchronisation (REAR) is not possible when
the preflash function is used. There is no setting or display for this mode
on the flash unit.
12 Automatic AF measuring beam
The automatic AF measuring beam is activated in the flash unit by the camera
when the ambient lighting conditions become inadequate for automatic focu-
sing. It projects onto the subject a striped pattern that the camera can use to
focus. Depending on the camera’s activated AF sensor, the AF beam has a ran-
ge of approximately 6 m to 9 m (with a standard 1.7/50 mm lens). The maxi-
mum flash range is reached with the camera’s central AF sensor. Parallax error
between lens and AF measuring beam limits the close-up range with the AF
measuring beam to approximately 0.7 m to 1 m.
If the automatic AF measuring beam is to be activated by the camera,
the „single AF (S)“ autofocus mode must be set on the camera and the
flash unit must indicate flash readiness. Some camera models support
only the camera’s internal AF measuring beam. In this case, the automa-
tic AF measuring beam of the flash unit is not activated (as in the case of
compact cameras; see the camera’s operating instructions).
Low-speed zoom lenses can significantly curtail the range of the AF measuring
beam!
Some cameras support the AF measuring beam in the flash unit only with the
camera’s central AF sensor. If a peripheral AF sensor is selected, then the AF
measuring beam will not be activated in the flash unit!
13 Triggering control (auto-flash)
On some cameras the flash will not be fired when the prevailing light is suffi-
cient for an exposure. When the camera shutter release is depressed, no flash
exposure is triggered.
In various cameras the triggering control only works in the full program mode
or „P“ program or must be activated on the camera (see camera operating
instructions).
14 Care and maintenance
Remove dust and grime with a soft dry cloth or silicon-treated cloth. Do not use
cleaning agents as these may damage the plastic parts.
14.1 Firmware updates
The flash unit’s firmware can be updated through the USB port
and adjusted
to the technical requirements of future cameras (Firmware Update).
For more information, visit the Metz homepage at www.metz.de.
14.2 Reset
The flash unit can be reset to the factory settings when delivered. Press the
ìModeî button for ca. 5 seconds. After ca. 5 seconds „rES“ (= Reset) is shown in
the display and the flash unit is reset to the settings as delivered..
This will not affect the firmware updates for the flash unit.
14.3 Flash capacitor forming
The flash capacitor built into the flash unit undergoes physical change if the unit
is not switched on for a prolonged period. For this reason it is necessary to
switch the unit on for approximately 10 minutes at least once every three
months. The power supplied by the power source must be sufficient to cause the
flash readiness indicator to light up no more than one minute after the flash unit
is switched on.
707 47 0081.A2 48AF-1Nikon/Inh. 19.09.2007 12:42 Uhr Seite 84
84


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metz MECABLITZ 48 AF-1 digital Nikon at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metz MECABLITZ 48 AF-1 digital Nikon in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 1,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info