Limpar regularmente a balança com un pano húmido, evitando que entre agua dentro da carcassa. O prato pode
tirar-se e lavar-se normalmente com água e um limpador normal.
Se a balança presenta uma mensagem de erro, apague-a e
volte a ligá-la após unos 5 segundos. Se a mensagem de
erro permanecer, proceda segundo se indica na tabela
seguinte.
Lista de mensagens de erro:
E11 RAM error
E16 ROM error
E18 EEPROM error
Chamar o serviço da
METTLERTOLEDO(BIPOR
TO)
E34 nº PLU excesso Nº PLU 1~`100
No PLU PLU não existe Programar PLU
nnnnnn
no visor
de peso
sobrecarga
Tire peso do prato
uuuuuu peso negativo Colocar a zero
Capacidade: 3kg, 6kg, 15kg o 30kg
Divisões: 1g, 2g, 5g o 10g
Visor de peso: 6 dígitos
Visor preço/kg: 6 dígitos
Visor de valor total: 6 dígitos
Temperatura de trabalho:-10
o
C~+40
o
C
Temperatura armazenagem:-25
o
C~+50
o
C
Alimentação: 12VDC~14VDC
Consumo: 20mA
Corrente de carga: 500mA
Adaptador de rede: I/P: 230VAC 50HZ
O/P:12VDC/800mA
Modificações técnicas e de fornecimento
reservadas.
Manten
ç
ão
Mensa
g
ens de erro
Es
p
ecifica
ç
ões
61


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mettler-Toledo Tiger II - RN10-CNTRS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mettler-Toledo Tiger II - RN10-CNTRS in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 1,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info