To ensure trouble free operation of the printer gap sensor, and to achieve normal print
head life, no pre printing should be placed on the label in the gap sensor path or in
areas which will be printed by the scale printer (see following figure). However, since
preprinting is commonly used by many customers the following guidelines must be
followed.
1. Inks used for preprinting must be specially formulated for use in thermal printers. If
proper inks are not used they can adhere to the print head. This ink build up on the
print head will interfere with heat transfer from the print head to the paper and cause
printing elements to burn out. Another problem with inks not formulated for thermal
printing is that they can contain chemicals which will cause the glass overcoat to chip
off of the print head, causing failure to print in the chipped areas.
2. If black ink is used in preprinting in the gap sensor path shown in the figure below, a
dense black stripe will have to be printed on the back of the liner, as shown in the Black
Stripe figure, to prevent the gap sensor from being affected by the black preprinting.
(Colors other than black might also be a problem and should be tested by the
customer) The black stripe must have gaps which correspond to the label gaps. The
black stripe on the liner must have a minimum transmission optical density of 2.3 and
must be uniform. In addition, the gap sensor circuit will need to be adjusted for
operation with the black stripe as explained in the product service manual. This
adjustment will need to be checked any time label paper is changed, for example when
labels are procured from a new supplier.
GAP SENSOR PATH BLACK STRIPE
62


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mettler-Toledo bPro at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mettler-Toledo bPro in the language / languages: English as an attachment in your email.

The manual is 2,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info