598222
11
Zoom out
Zoom in
Previous page
1/17
Next page
Chapter II
MX 650 / MX 655
24
4.4. Measurement of direct current (MX 655 only)
1000
600
600
750
1000
V
1000
MAXMIN
40
400
600
A
1mS
PEAK
Hz
REL
HOLD
Set the switch to 1000 A .
Press on the / button to
display the symbol (direct
signal).
Once the display is stabilised,
press on the
REL button to
automatically reset the DC zero.
Then follow the same procedure
as for measuring alternating
current.
See previous §.
Note: The correct connection
direction to obtain a positive
value is indicated on the right-
hand jaw.
4.5. Measuring resistance
600V
750
1000
PEAK
1mS
400
40
A
REL
Hz
1000
V
600 1000
HOLD
600
Set the switch to .
Connect the red test lead to the
"+" input terminal and the black
test lead to the "COM" input
terminal.
Place the touch prods in contact
with the points to be measured
and read the result on the
display.
Note: Always ensure that the
circuit is disconnected from the
power supply before measuring
resistance!
To measure low resistances, it
is preferable to offset the
resistance of the measurement
leads.
To do this, short-circuit the lead
touch prods then press the
REL button before taking the
measurements.
12.00
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrix MX 655 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrix MX 655 in the language / languages: English as an attachment in your email.

The manual is 0,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info