598222
4
Zoom out
Zoom in
Previous page
1/17
Next page
Chapter II
MX 650 / MX 655
17
1. GENERAL INSTRUCTIONS
1.1. Precautions and safety measures
1.1.1. Before using
You have just acquired a 4,000-count multimeter clamp. We
thank you for your confidence.
This multimeter clamp complies with the IEC 61010 norms
concerning electronic measuring instruments. For your own
safety and to prevent damage to the instrument, you must
follow the instructions given in this manual.
This instrument can be used for measuring category III
installation circuits, in an environment with a pollution
degree of 2 and with a voltage no higher than 600 V in
relation to the earth.
Definition of the installation categories
(see IEC 61010-1 publication):
CAT I: CAT I circuits are circuits protected by low level
transient -voltage surge limiters
Example: protected electronic circuits
CAT II
: CAT II circuits are household or similar appliance
power circuits, which may carry medium-level transient
voltage surge.
Example: household appliance and portable tool power
supplies
CAT III : CAT III circuits are high-power appliance power
circuits, which may carry high-level transient voltage
surges.
Example: industrial machinery or instrument power
supplies
CAT IV : CAT IV circuits are circuits which can carry very
substantial transient -voltage surges.
Example: power feeders
For safety reasons, you should only use leads that comply with
the IEC 61010 standard.
Before using, always check that they are in perfect working
order.
1.1.2. When using the instrument
Never exceed the protection limit values indicated in the
specifications for each type of measurement.
When the multimeter clamp is linked to the measurement
circuits, do not touch any unused terminals.
Before changing the function, disconnect the measure-
ment leads from the circuit measured.
Never measure resistances on a live circuit.
1.1.3. Symbols
Refer to the user's manual
Risk of electric shock
Double insulation
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrix MX 655 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrix MX 655 in the language / languages: English as an attachment in your email.

The manual is 0,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info