598209
9
Zoom out
Zoom in
Previous page
1/20
Next page
Chapter II
Portable digital multimeter 21
3. COMMISSIONING
3.1. Connecting the test leads
Connect
the black lead to the COM socket (for all measurements). Depending on the position of
the selector switch, connect the red lead as follows:
Rotary selector switch position Input terminal
V
AC
, mV
DC
, V
DC
, Ω,
VΩ
10 A
DC
10 A
5 mA
DC
, 50 mA
DC
, 500 mA
DC
500 mA
3.2.
Switching on the instrument
Turn the selector switch to the required function.
All segments of the display come on for a few seconds. The instrument is then ready for
measurements.
3.3. Switching off the instrument
The instrument can be switched off manually by returning the selector switch to the OFF
position, or automatically after approximately half an hour if no key is pressed or the switch is not
operated.
)
Note Automatic shutdown of the instrument is disabled in order to avoid
interrupting the peak value measurements (Pk +/-), or the data print out.
For user safety, automatic shutdown is also disabled when a measured
magnitude (voltage/current) present at the input exceeds dangerous level
(
indicator displayed).
3.4. Special configurations
To adapt the configuration of the instrument to the measurement environment, the user can
choose 50 Hz or 60 Hz rejection :
Switch on with the rotary switch while holding down the HOLD key.
The selection :
is reversed from the last configuration
is displayed for two seconds
remains backed up in non-volatile memory.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrix MX 58HD at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrix MX 58HD in the language / languages: English as an attachment in your email.

The manual is 0,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Metrix MX 58HD

Metrix MX 58HD User Manual - German - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info