598211
16
Zoom out
Zoom in
Previous page
1/19
Next page
Chapter II
28 Portable digital multimeters
5.2.5. Resistance / Continuity test
Selector switch
position
Ranges Accuracy
Measurement
current
Protection
(∗)
Resolution
500
0.3 % R + 3 D 1 mA
0.1
500
1 mA
0.1
5 k
100 µA
1
50 k
10 µA
10
500 k
0.3 % R + 3 D
1 µA
100
5 M
0.5 % R + 3 D 100 nA
1 k
50 M
1 % R + 5 D 50 nA
600 VRMS
10 k
(∗) Overload protection can be reset automatically.
Number of count : 5000
Range selection : automatic or manual (fixed in continuity mode)
Maximum open circuit voltage : 4 V
Detection threshold in continuity mode : 10 to 20
Response time in continuity mode : < 10 ms
For measurements in 5 M and 50 M ranges, the use of shielded connection is highly
recommended.
5.2.6. Capacitance
Note Discharge all capacitors before taking measurements.
Selector switch
position
Ranges
Accuracy
Measurement
current
Max m
easurement
time
Protection
(∗)
Resolution
50 nF 100 nA < 1 s 10 pF
500 nF 1 µA < 1 s 100 pF
5 µF 10 µA < 1 s 1 nF
50 µF 100 µA < 1 s 10 nF
500 µF 1 mA < 2 s 100 nF
5000 µF
1 mA
3 s/mF
1 µF
50 mF
1 % R + 4 D
1 mA
3 s/mF
600 VRMS
10 µF
(∗) Overload protection can be reset automatically.
To reduce the influence of the ambient electromagnetic fields on the measurement, it is
recommended to use shielded cables for measurements in 50 nF range.
Number of count : 5000
Range selection : automatic or manual
Maximum open circuit voltage : 4 V
5.2.7. Diode threshold voltage measurement
Measurable voltages : 0 to 1.999 V
Measurement current : 1 mA ± 20 %
Resolution : 1 mV
Protection : 600 V
RMS, can be reset automatically
OL : displays at 4 V
The battery can be tested without leads if : 03.8 V < V battery < OL
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrix MX 23 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrix MX 23 in the language / languages: English as an attachment in your email.

The manual is 0,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Metrix MX 23

Metrix MX 23 User Manual - German - 19 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info