Portable 4000 count digital multimeter
22
3.3 Resistance
measurement
Never test a resistance on a live circuit.
Connect the leads - preferably twisted - to the multimeter
(COM
and Ω terminals) and to the circuit or the component to be tested.
Position the selector switch on the ohmmeter function “ Ω
”.
Automatic range selection : read the measured value.
Memorise the value, if necessary, by pressing the “ MEM ” key.
Overload : the beep sounds and “ OL.
blinks.
Range
400 Ω 4 kΩ 40 kΩ 400 kΩ 4 MΩ 40 MΩ
Resolution
0.1 Ω 1 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ
Accuracy ± 0.5 % R ± 4 D
± 1 % R
± 5 D
± 2 % R
± 5 D
Voltage on
open circuit
< 2 V
Measuremen
t current
0.4 mA
Protection 600 Vrms
3.4
Continuity sound test
Connect the leads to the multimeter (COM and Ω terminals) and to
the circuit or the component to be tested.
Position the selector switch on the continuity sound function “
”.
Audible beep when R < 40 Ω
.
Protection : 600 Vrms.
Output voltage in open circuit < 2 V
Overload : “ OL.or every segments of the bargraph are display
ed.
3.5 Diode test
Never test a diode on a live circuit.
With this function, it is not only possible to test classic diodes, but also
LED’s or any other semiconductor in which the junction corresponds
to a direct voltage less than 3 V.
Connect the leads to the multimeter (COM and
terminals) and
to the circuit or component to be tested.
Position the selector switch on the “
” function.
Max. output voltage : 4 V in open circuit
Short-circuit current : 1 mA
Overload : the beep sounds and “ OL.
blinks.
Memorise, if necessary, by pressing the “ MEM ” key.
Protection : 600 Vrms.
3.6 Frequency measurement
Connect the leads to the multimeter (COM and V terminals) and to
the circuit the frequency
of which is to be tested.
Position the selector switch on the “ Hz ” function.
Automatic range selection : read the measured value.
Memorise, if necessary, by pressing the “ MEM ” key.
Overload : “ OL.
blinks.
...
/...
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrix MX 22 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrix MX 22 in the language / languages: English as an attachment in your email.

The manual is 0,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Metrix MX 22

Metrix MX 22 User Manual - German - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info