MI 3100 s, MI 3100 SE EurotestEASI Data handling
62
7 Data handling (MI 3100 SE only)
7.1 Memory organization
Measurement results together with all relevant parameters can be stored in the instrument’s
memory. After the measurement is completed, results can be stored to the flash memory of the
instrument, together with the sub-results and function parameters.
7.2 Data structure
The instrument’s memory place is divided into 4 levels each containing 199 locations. The
number of measurements that can be stored into one location is not limited.
The data structure field describes the location of the measurement (which object, block, fuse
and connection) and where can be accessed.
In the measurement field there is information about type and number of measurements that
belong to the selected structure element (object and block and fuse and connection).
The main advantages of this system are:
Test results can be organized and grouped in a structured manner that reflects the
structure of typical electrical installations.
Customized names of data structure elements can be uploaded from EurolinkPRO
PCSW.
Simple browsing through structure and results.
Test reports can be created with no or little modifications after downloading results to a
PC.
Figure 7.1: Data structure and measurement fields
Data structure field
Memory operation menu
Data structure field
1st level:
OBJECT: Default location name (object and its successive
number).
001: No. of selected element.
2nd level:
BLOCK: Default location name (block and its successive
number).
002: No. of selected element.
3rd level:
FUSE: Default location name (fuse and its successive
number).
003: No. of selected element.
62


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrel MI3100S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrel MI3100S in the language / languages: English as an attachment in your email.

The manual is 1.81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Metrel MI3100S

Metrel MI3100S User Manual - German - 92 pages

Metrel MI3100S User Manual - Dutch - 25 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info