MI 3152(H) EurotestXC (2,5 kV) Appendix A Commanders
84
Figuur D.3: Voorkant meetsteker met bediening (A 1314)
Figuur D.4: Achterkant
1
TEST
TEST
Start de meting.
Wordt gebruikt als PE aanraak elektrode.
2
LED
Linker status RGB LED
3
LED
Rechter status RGB LED
4
LEDs
Lamp LEDs (Meetpen met bediening)
5
Functie selector
Selecteert de test functie.
6
MEM
Bewaren /opvragen/ verwijderen van resultaten in het geheugen
van het instrument.
7
BL
Schakelt de achtergrondverlichting aan of uit.
8
Lamp toets
Schakelt het lampje op de meetpen aan of uit.
9
Batterijen
Formaat AAA, alkaline/ oplaadbare Ni-MH
10
Batterij deksel
Batterij compartiment deksel
11
Cap
Verwijderbare CAT IV kapje (Meetpen met bediening)
A.4 Bediening van de meetpen
Beide LED’s geel
Waarschuwing! Gevaarlijke spanning op de meetpen PE
aansluiting
Rechter LED rood
Indicator afkeuring
Rechter LED groen
Indicator goedkeuring
Linker LED knippert blauw
Meetpen is de inkomende spanning aan het monitoren.
Linker LED oranje
Spanning tussen de test aansluitingen is hoger dan 50V.
Beide LEDs knipperen rood
Batterij bijna leeg
Beide LEDs rood en uit
Batterij spanning te laag voor functioneren van meetpen
84


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrel MI 3152H - EurotestXC 2.5 kV at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrel MI 3152H - EurotestXC 2.5 kV in the language / languages: Dutch as an attachment in your email.

The manual is 3.64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Metrel MI 3152H - EurotestXC 2.5 kV

Metrel MI 3152H - EurotestXC 2.5 kV User Manual - English - 204 pages

Metrel MI 3152H - EurotestXC 2.5 kV User Manual - German - 213 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info