MI 3152(H) EurotestXC (2,5 kV) Appendix A Profile notes
193
Appendix A Profile Notes
Instrument supports working with multiple Profiles. This appendix contains collection of minor
modifications related to particular country requirements. Some of the modifications mean
modified listed function characteristics related to main chapters and others are additional
functions. Some minor modifications are related also to different requirements of the same
market that are covered by various suppliers.
A.1 Profile Austria (ALAJ)
Testing special delayed G type RCD supported.
Modifications in chapter 7.7 Testing RCDs.
Special delayed G type RCD selection added in the Selectivity parameter in Test Parameters /
Limits section as follows:
Selectivity
Characteristic [--, S, G]
Time limits are the same as for general type RCD and contact voltage is calculated the same as
for general type RCD.
Selective (time delayed) RCDs and RCDs with (G) - time delayed characteristic demonstrate
delayed response characteristics. They contain residual current integrating mechanism for
generation of delayed trip out. However, contact voltage pre-test in the measuring procedure
also influences the RCD and it takes a period to recover into idle state. Time delay of 30 s is
inserted before performing trip-out test to recover S type RCD after pre-tests and time delay of 5
s is inserted for the same purpose for G type RCD.
Table 7.1: Relationship between Uc and I
N changed as follows:
RCD type
Contact voltage
Uc proportional to
Rated IN
Notes
AC, EV, MI (a.c. part)
--
G
1.05IN
any
All models
AC
S
21.05IN
A, F
--
G
1.41.05IN
30 mA
A, F
S
21.41.05IN
A, F
--
G
21.05IN
< 30 mA
A, F
S
221.05IN
B, B+
--
21.05IN
any
Model MI 3152
only
B, B+
S
221.05IN
Technical specifications unchanged.
194


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrel MI 3152 - EurotestXC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrel MI 3152 - EurotestXC in the language / languages: English as an attachment in your email.

The manual is 6.49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Metrel MI 3152 - EurotestXC

Metrel MI 3152 - EurotestXC User Manual - German - 213 pages

Metrel MI 3152 - EurotestXC User Manual - Dutch - 85 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info