MI 3152(H) EurotestXC (2,5 kV) Technical specifications
190
12.22 Varistor test
Udc DC Voltage
Measuring range (V)
Resolution (V)
Accuracy
0 … 1000 (2500)*
1
(3 % of reading + 3 digits)
Uac AC voltage
Measuring range (V)
Resolution (V)
Accuracy
0 … 625 (1562)*
1
Consider accuracy of Udc
* MI 3152H only
Measurement principle .................... d.c. voltage ramp
Test voltage slope ........................... Nominal test voltage up to 1000 Vdc : 100 Vdc/s
Nominal test voltage 2500 Vdc : 350 Vdc/s (MI 3152H only)
Threshold current ............................ 1 mA
12.23 ISFL – First fault leakage current (MI 3152 only)
Isc1, Isc2 First fault leakage current
Measuring range (mA)
Resolution (mA)
Accuracy
0.0 ... 19.9
0.1
±(5 % of reading + 3 digits)
Measuring resistance .................................. approx. 390
Nominal voltage ranges .............................. 93 V UL1-L2 134 V
185 V UL1-L2 266 V
12.24 IMD (MI 3152 only)
R1, R2 Threshold insulation resistance
R (kΩ)
Resolution (kΩ)
Note
5 ... 640
5
up to 128 steps
I1, I2 First fault leakage current at threshold insulation resistance
I (mA)
Resolution (mA)
Note
0.0 ... 19.9
0.1
calculated value*)
t1, t2 Activation / disconnection time of IMD
t1, t2 (s)
Resolution (s)
Accuracy
0.00 ... 19.99
0.01
± 0.01 s
20.0 … 99.9
0.1
± 0.1 s
Nominal voltage ranges .............................. 93 V UL1-L2 134 V
185 V UL1-L2 266 V
*)See chapter 7.22 IMD Testing of insulation monitoring devices (MI 3152 only) for more
information about calculation of first fault leakage current at threshold insulation resistance.
191


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrel MI 3152 - EurotestXC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrel MI 3152 - EurotestXC in the language / languages: English as an attachment in your email.

The manual is 6.49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Metrel MI 3152 - EurotestXC

Metrel MI 3152 - EurotestXC User Manual - German - 213 pages

Metrel MI 3152 - EurotestXC User Manual - Dutch - 85 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info