9 Technical specifications
9.1 Insulation resistance (of PV systems) RISO - and RISO +
Insulation resistance (nominal voltages 50 VDC, 100 VDC and 250 VDC)
Measuring range according to EN61557 is 0.15 M 199.9 M.
Measuring range (M) Resolution (M) Accuracy
0.00 19.99 0.01 (5 % of reading + 3 digits)
20.0 99.9 0.1 (10 % of reading)
100.0 199.9 (20 % of reading)
Insulation resistance (nominal voltages 500 VDC and 1000 VDC)
Measuring range according to EN61557 is 0.15 M 1 G.
Measuring range (M) Resolution (M) Accuracy
0.00 19.99 0.01 (5 % of reading + 3 digits)
20.0 199.9 0.1 (5 % of reading)
200 999 1 (10 % of reading)
Voltage
Measuring range (V) Resolution (V) Accuracy
0 1200 1 (3 % of reading + 3 digits)
Nominal voltages ............................... 50 VDC, 100 VDC, 250 VDC, 500 VDC, 1000 VDC
Open circuit voltage ........................... -0 % / +20 % of nominal voltage
Measuring current .............................. min. 1 mA at RN=UN1 k/V
Short circuit current ........................... max. 3 mA
The number of possible tests ............ > 1200, with a fully charged battery
Auto discharge after test.
Specified accuracy is valid if 3-wire test lead is used while it is valid up to 100 M if tip
commander is used.
Specified accuracy is valid up to 100 M if relative humidity > 85 %.
In case the instrument gets moistened, the results could be impaired. In such case, it is
recommended to dry the instrument and accessories for at least 24 hours.
The error in operating conditions could be at most the error for reference conditions
(specified in the manual for each function) 5 % of measured value.
The insulation resistance results in Autotest may slightly differ in comparison to results
in Single test mode because of the three wire connection and the internal resistance of
the measuring instrument.
66


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrel MI 3109 - Eurotest PV Lite at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrel MI 3109 - Eurotest PV Lite in the language / languages: English as an attachment in your email.

The manual is 1.66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Metrel MI 3109 - Eurotest PV Lite

Metrel MI 3109 - Eurotest PV Lite Quick start guide - Dutch - 68 pages

Metrel MI 3109 - Eurotest PV Lite User Manual - Dutch - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info