MI 3109 EurotestPV Lite Safety and operational considerations
7
All normal safety precautions must be taken in order to avoid risk of
electric shock while working on electrical installations!
PV sources can produce very high voltages and currents. Only skilled and
trained personnel should perform measurements on photovoltaic systems.
Local regulations should be considered.
Safety precautions for working on the roof should be considered.
In case of a fault in the measuring system (wires, devices, connections,
measuring instrument, accessories…), presence of flammable gases, very
high moisture or heavy dust an electrical arc can occur that will not
extinguish by itself. Arcs can lead to fire and can cause heavy damage.
Users must be skilled to disconnect the PV system safely in this case.
Use only dedicated measuring accessories for testing on PV electrical
installations. Metrel accessories for PV installations have yellow marked
connectors.
Consider that protection category of some accessories is lower than of the
instrument. Test tips have removable caps. If they are removed the
protection falls to CAT II. Check markings on accessories!
(cap off, 18 mm tip)…CAT II up to 1000 V
(cap on, 4 mm tip)… CAT II 1000 V / CAT III 600 V / CAT IV 300 V
PV Safety probe A 1384 provides additional safety when working on PV
installations. It has an inbuilt protective circuit that safely disconnects the
instrument from the PV installation in case of a failure in the instrument
(see chapter 4.4.8 Accessories for more information).
PV test lead A1385 has integrated fuses that safely disconnects instrument
from the PV installation in case of a failure in the instrument.
If a voltage higher than 1000 V d.c. is detected on any of the measuring
inputs further measurements will be blocked and the
warning is displayed.
Warnings related to safety of measurement functions:
Insulation resistance of PV systems
Do not touch the test object during the measurement or before it is fully
discharged! Risk of electric shock!
When an insulation resistance measurement has been performed on a
capacitive object, automatic discharge may not be done immediately! The
warning message and the actual voltage are displayed during
discharge until voltage drops below 10 V.
Continuity functions
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrel MI 3109 - Eurotest PV Lite at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrel MI 3109 - Eurotest PV Lite in the language / languages: English as an attachment in your email.

The manual is 1.66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Metrel MI 3109 - Eurotest PV Lite

Metrel MI 3109 - Eurotest PV Lite Quick start guide - Dutch - 68 pages

Metrel MI 3109 - Eurotest PV Lite User Manual - Dutch - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info