MD 9040 & MD 9050 Digital multimeter Specification
19
6 Specification
General Specifications
Display: 9999 counts: ACV, DCV, Hz & nS
6000 counts: mV, μA, mA, A, Ohm & Capacitance
Polarity: Automatic
Update Rate: Digital Display: 5 per second nominal;
41 Segments Bar-graph: 60 per second max
Low Battery: Below approx. 7V
Operating Temperature: 0oC to 45oC
Relative Humidity: Maximum relative humidity 80% for temperature up to 31oC
decreasing linearly to 50% relative humidity at 45oC
Pollution degree: 2
Storage Temperature: -20oC to 60oC, < 80% R.H. (with battery removed)
Altitude: Operating below 2000m
Temperature Coefficient: nominal 0.15 x (specified accuracy)/ oC @(0oC ~ 18oC or
28oC ~ 45oC), or otherwise specified
Sensing: MD 9050: AC+DC True RMS
MD 9040: AC True RMS
Safety: Double insulation per IEC61010-1 2nd Ed., EN61010-1 2nd
Ed., UL61010-1 2nd Ed. & CAN/CSA C22.2 No. 61010.1-
0.92 to Category IV 1000Vac & Vdc.
Transient protection: 12kV (1.2/50μs surge)
MD 9040 & MD 9050 Terminals (to COM) Measurement Category:
V : Category IV 1000Vac & Vdc
mAμA : Category IV 600Vac and 300Vdc
A : Category IV 600Vac and 500Vdc
Overload Protections:
MD 9050, MD 9040:
μA & mA: 1A/600Vac, IR 100kA, F fuse
A: 10A/600Vac, IR 100kA, F fuse
V: 1050Vrms, 1450Vpeak
mV, Ω, & Others: 600Vdc and Vac rms
E.M.C. : Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-
3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, , EN61000-
4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11)
In an RF field of 3V/m:
Capacitance function is not specified
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrel MD9040 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrel MD9040 in the language / languages: English, German as an attachment in your email.

The manual is 5.31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info