585248
11
Zoom out
Zoom in
Previous page
1/68
Next page
11
ENGLISH
indicate component parts;
are consecutively numbered; and
refer to the corresponding numbers in
brackets (1), (2), (3) ... in the neigh-
bouring text.
Numbered steps must be carried out in
sequence.
Instructions which can be carried out in
any order are indicated by bullet points (•).
List items are indicated by dashes (–).
3.1 Specified conditions of use
The pump is intended solely for private use
for draining flooded house and garden are-
as.
Approved pumping media
Submersible clean water pumps: clean water
Submersible dirty water pumps:
clean or dirty water.
The suspended solids content in the dirty
water must not exceed 5%.
The particle sizes of the solids in the dirty
water must not exceed the maximum par-
ticle size specified in the technical data.
Any other use is considered to be not as
specified and not allowed.
Typical application areas
Drainage of containers, water tanks,
swimming pools, soakaways and flooded
rooms
Irrigation of gardens and lawns.
Unspecified use
The pump is not intended for:
pumping fluids at a temperature > 35°C;
supplying drinking water or pumping liquid
food;
pumping salt water;
pumping explosive, inflammable, aggres-
sive or health-damaging substances or
human waste;
commercial or industrial use; or
continuous circulation (pond).
The pump should not be used by people (in-
cluding children and youths) who:
have physical and/or mental impairments;
have impaired senses;
do not have adequate experience and/or
knowledge in handling the pump; or
have not read and understood the operat-
ing instructions.
The manufacturer assumes no liability for
damage caused by unspecified use.
Unspecified use, modification of the pump or
use of parts that have not been tested and
approved by the manufacturer can cause un-
foreseeable damage!
3.2 General safety instructions
When using this pump observe the follow-
ing safety instructions to exclude the risk
of personal injury or material damage.
Follow the legal guidelines or accident
prevention regulations for use of submers-
ible pumps.
When the pump is being used in swim-
ming pools and garden ponds and in the
protected areas around them, the regula-
tions must be observed in accordance
with DIN VDE 0100-702 and -738.
All local regulations pertaining to the safe
operation of submersible pumps must also
be followed.
The pump must be protected by a residual
current device (RCD) with a trip current of
max 30 mA.
AGeneral danger!
Do not operate the pump if anyone is in con-
tact with the pumping media (e.g. in the
swimming pool or garden pond)!
The following residual risks do principally ex-
ist when operating submersible pumps and
can not be fully eliminated – even by em-
ploying safety devices.
ADanger from the environment!
Do not use the pump in hazardous locations
or near inflammable liquids and gases!
ADanger: Hot water!
If the shut-off pressure of the pressure
switch cannot be reached due to poor pres-
sure conditions or a defective pressure
switch the water can heat up within the pump
as a result of internal circulation.
Through this the pump and the connection
lines can become damaged or leaky, allow-
ing hot water to escape. Danger of scalding!
Do not operate the pump against a closed
pressure line for longer than 5 minutes.
Unplug the pump and allow to cool. A spe-
cialist must check the system to make
sure it is in perfect working order before it
can be used again.
3. Safety
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metabo PS15000S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metabo PS15000S in the language / languages: English, German, Dutch, Danish, French, Swedish as an attachment in your email.

The manual is 0,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info