ENGLISH
6.1 LED Indicators
LED check:
When turning On a LED check is
carried out.
Both indicators are illuminated for
one second (LED check). As soon
as the yellow LED "Overload" extin-
guishes the machine is operational.
Green LED "Mains" illuminated.
Machine is operational.
Yellow LED "Overload" flashes.
Overload protection tripped. When
the yellow LED extinguishes, weld-
ing can resume.
Green LED "Mains" flashes.
The gun's trigger switch was
pressed and held during an over-
load period. Release trigger switch:
The machine is operational again.
The trigger switch was pressed
twice too quickly.
Press trigger switch again.
6.2 Setting the Welding
Parameters
The operational parameters are set at
the control panel.
Wire feed
With the wire feed potentiometer the
speed of the wire feed is adjusted.
Wire feed setting range:
approx. 0... 20 m/min.
On the MIG/MAG 150/20 XT, MIG/MAG
165 SP the wire feed speed depends
also on the set welding step.
Welding current (voltage)
The welding current (voltage) is set with
the welding step selector switch:
MIG/MAG 150/20 XT
6 steps
MIG/MAG 170/30 XTC (Combi),
MIG/MAG 165 SP
12 steps
6 steps at 230 V
6 steps at 400 V
MIG/MAG 200/40 XT, MIG/MAG 250/60
XT, MIG/MAG 300/45 XT
12 steps
2 coarse steps
6 fine steps
6.3 Backburn Time
When correctly set the backburn time
prevents the electrode wire from sticking
to the weld pool. Setting is adjusted by
the backburn time potentiometer (51).
Backburn time potentiometer knob
(51) turned fully to the
left = minimum backburn time.
Backburn time potentiometer knob
(51) turned fully to the
right = maximum backburn time.
6.4 Gas-shielded Arc Weld-
ing
A
Caution!
Always check before starting work:
Correct electrode wire installed?
Correct shielding gas connected?
Gun correctly equipped (liner, spi-
ral, tip/shroud and guide tube)?
1. Attach earth cable at a suitable loca-
tion to the workpiece.
2. Open cylinder valve and set desired
gas flow rate.
Change gas shroud, if necessary.
Rule of thumb for calculating the
required amount of shielding gas
Amount of shielding gas [l/min] =
10 x wire diameter [mm]
Example:
Electrode wire diameter 1 mm
required amount of shielding gas 10 l/min
Diagram for the exact determination
of the shielding gas amount required
3. Set the welding current (voltage).
A
Caution!
Never actuate the welding current
(voltage) step switch during the run-
ning welding process.
Switching under load causes an over-
load and damages the switches.
4. Select desired operating mode.
5. Set the wire feed speed.
6. Turn machine on at the main switch.
The welding machine is now opera-
tional.
2-step mode (manual welding)
1. Press and hold trigger switch;
the welding process starts.
2. Release trigger switch;
the welding process ends.
4-step mode (continuous welding)
1. Press and release trigger switch;
the welding process starts.
2. Press and release trigger switch
again;the welding process ends.
Spot weld mode
1. Set the weld time.
2. Press trigger switch;
the spot welding starts.
The welding process ends automati-
cally after the set weld time.
3
Note:
Releasing the trigger switch
before the set weld time is over also
ends the welding process.
6.5 Shutting Down
1. Close gas cylinder valve.
2. Turn machine OFF at the main
switch.
3. Disconnect earth cable from work-
piece.
4. Unplug power cable.
This welding machine contains no user-
serviceable parts.
Depending on dust build-up it should be
blown out every 4 to 6 months with dry
compressed air.
Periodically check the machine for visi-
ble defects.
Contact a qualified electrician if any of
the cables are damaged.
For these MIG/MAG welding machines
we recommend the following accesso-
ries. They have been tested with the
machines and ensure unproblematic
operation.
51
Amount of shielding gas in l/min
Aluminium Steel
Current in A
Gas shroud diameter
in mm
7. Maintenance
8. Available Accessories
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metabo MIG MAG 150-20 XT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metabo MIG MAG 150-20 XT in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 4,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info