ENGLISH
1. Machine Overview.......................9
2. Please Read First! .....................10
3. Range of Application and
Pumping Media..........................10
4. Safety .........................................10
4.1 Specified conditions of use .........10
4.2 General safety instructions..........10
5. Prior to Operation .....................11
5.1 Installation...................................11
5.2 Suction line connection ...............11
5.3 Discharge hose connection.........11
5.4 Connection to a pipe system.......11
5.5 Mains connection ........................11
5.6 Filling the pump and priming .......11
6. Operation ...................................11
6.1 Commissioning............................11
6.2 Pump characteristic curve...........12
7. Care and Maintenance ..............12
7.1 Periodic maintenance..................12
7.2 Danger of freezing.......................12
7.3 Equipment dismounting and
storing .........................................12
8. Trouble Shooting ......................12
8.1 Fault finding.................................12
8.2 Pressure switch adjustment ........12
8.3 Increasing the air charge.............13
9. Repairs .......................................13
10. Environmental Protection ........13
11. Available Accessories .........13/66
12. Technical Specifications ..........14
Read these instructions before use.
Pay special attention to the safety
instructions.
Disregard of the operating instruc-
tions invalidates the manufacturer's
warranty; the manufacturer is not
liable for any damages resulting
from such disregard.
If you notice shipping damage while
unpacking, notify your supplier
immediately. Do not operate the
machine!
Dispose of the packing in an envi-
ronmentally friendly manner. Take
to a proper collecting point.
Keep these instructions for refer-
ence on any issues you may be
uncertain about.
If you lend or sell this machine be
sure to have the instructions go with
it.
This equipment is intended for pumping
clear water in domestic applications,
such as
irrigation,
well, rain and service water pump-
ing,
draining of pools, garden ponds and
water tanks.
The max. permissible temperature of the
pumped medium is 35 °C.
4.1 Specified conditions of
use
This equipment must not be used to sup-
ply drinking water or for pumping food-
stuff.
Explosive, inflammable, aggressive flu-
ids or substances detrimental to health
and salt water must not be pumped.
This equipment is not suitable for com-
mercial or industrial use.
Alteration of the equipment or use of
parts not approved by the equipment
manufacturer is not permitted.
Any inexpert use the equipment is not as
specified; it can cause unforeseen dam-
age!
4.2 General safety instruc-
tions
Children, juveniles and persons not fam-
ilar with the instructions are not permit-
ted to operate the pump.
When used in swimming pools and gar-
den ponds and their range of protection,
the regulations according to DIN VDE
0100 -702, -738 are to be observed.
When used as domestic water supply
any applicable local regulations pertain-
ing to water supply and waste water dis-
posal, plus DIN 1988 (where applicable)
are to be observed.
The following residual risks do principally
exist when operating pumps and pres-
sure vessels and can not be fully elimi-
nated – even by employing safety
devices.
A
Hazard by ambient conditions!
Do not expose to rain. Do not operate in
damp or wet environment.
Do not direct water jet directly against
the equipment or other electrical parts!
Risk of fatal electric shock!
Do not use the pump in hazardous loca-
tions or near inflammable liquids and
gases!
A
Danger: Hot water!
If the shut-off pressure of the pressure
switch cannot be reached due to poor
pressure conditions or a defective pres-
sure switch the water can heat up within
the pump as a result of internal circula-
tion.
Through this the pump and the connec-
tion lines can become damaged or
leaky, allowing hot water to escape.
Danger of scalding!
Do not operate the pump against a
closed pressure line for longer than
5 minutes.
Unplug the pump and allow to cool.
A specialist must check the system
to make sure it is in perfect working
order before it can be used again.
B
Danger! Risk of electric shock!
Always unplug before servicing.
Do not touch the plug with wet hands! To
unplug always pull on the plug, not the
power cable.
Do not buckle, squeeze, drag or drive
over power cable and extension cables;
protect from sharp edges.
A
Danger by pump failings!
Before each use check the equipment,
especially the power cable, plug and
electrical parts for possible damage.
Risk of fatal electric shock!
A damaged pump must be workmanlike
repaired before it can be used again.
Do not attempt to repair the equipment
yourself! Only trained specialists are
permitted to service or repair pumps or
pressure vessels.
A
Caution!
To avoid water damage, e.g.
flooded rooms, caused by pump mal-
functions or defects:
provide for suitable safety measures
such as the following:
alarm or
collection tank with monitoring.
The manufacturer is not liable for any
damage caused by:
improper use of the pump;
overloading of the pump through
continous operation;
failure to operate and store the
pump in a frost-free environment;
unauthorised modification of the
pump (repairs to electrical equip-
ment may only be carried out by
qualified electricians!);
use of spare parts which have not
been tested and approved by the
manufacturer; or
use of unsuitable installation materi-
als (fittings, connection lines etc.).
Table of Contents
2. Please Read First!
3. Range of Application and
Pumping Media
4. Safety
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metabo HWW 5500-50 M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metabo HWW 5500-50 M in the language / languages: English, German, Dutch, Danish, French, Swedish, Spanish, Finnish as an attachment in your email.

The manual is 5,85 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info