600831
13
Zoom out
Zoom in
Previous page
1/68
Next page
13
ENGLISH
A
Caution!
The factory-set cut-out pres-
sure must not be exceeded.
4. To change the cut-out pressure, turn
nut (12)
clockwise to increase the cut-out
pressure;
counter-clockwise to decrease
the cut-out pressure.
5. To change the cut-in pressure, turn
nut (13)
clockwise to increase the cut-in
pressure;
counter-clockwise to decrease
the cut-in pressure.
6. If necessary, repeat steps 2. to 5.
until the desired values are set.
7. Put the pressure switch cover back
on.
8.3 Increasing the air charge
If – during time – the pump starts after a
minimal amount of water (approx. 0.5 l)
is drawn off, the tank's air charge must
be increased.
3
Note:
The air charge pressure can not
be taken from the pressure gauge.
1. Unplug.
2. Open pressure line (open tap or
spray nozzle) and drain water com-
pletely.
3. Remove plastic cover from front of
tank to have access to the air charg-
ing valve.
4. Put air pump or air hose with tire
chuck and pressure gauge on the air
charging valve.
5. Pump up to the rated air charge
pressure (see "Technical Specifica-
tions").
6. Reconnect equipment and check for
proper functioning.
A
Danger!
Repairs to electric tools must
only be carried out by a qualified
electrician!
Electric tools in need of repair can be
sent to an authorised service center in
your country. See spare parts list for
address.
Please attach a description of the fault to
the electric tool.
For shipping:
Drain pump and tank completely
(see "Equipment dismounting and
storing").
Uninstall pressure switch and pres-
sure gauge (to prevent shipping
damage).
Ship equipment in original packing,
if possible.
The packaging of the pump can be
100 % recycled.
Worn out power tools and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on chlo-
rine-free bleached paper.
For this equipment the following acces-
sories are available at specialist dealers.
3
Note:
Illustrations and stock numbers
can be found at the end of these instruc-
tions.
A Pump Installation Package,
complete with double nipple, check
valve, pipe nipple 150 mm (2 pcs.),
filter long, washable filter cartridge,
spiral hose assembly 1 m, elbow,
hose bib with ball valve, thread
sealing tape.
B Dry-running Stop Switch,
with 10 m cable, keeps the pump
from running dry when pumping
from tank, pool, etc.
C Spiral Hose 1"
1) 1 m assembly, with quick
release screw fitting at both
ends;
2) 4 m, complete with quick
release screw fitting and
strainer with foot valve;
3) 7 m, complete with quick
release screw fitting and
strainer with foot valve.
D Filter, 1" connection, long,
complete with washable plastic fil-
ter cartridge.
E Disposable Filter Cartridge, long,
for mechanical preliminary filtering
of sand.
F Washable Filter cartridge, long,
for mechanical preliminary filtering
of sand, reusable.
G Activated Carbon Filter Cartridge,
long,
for use with chlorous water,
removes odours or discolouring.
H Filter Cartridge Poly, long,
filled with Polyphosphate, for calcif-
erous water supplied to water heat-
ers.
I Pipe Nipple 150 mm, 1" male at
both ends, galvanized, to connect
pump and filter.
J Double Nipple, 1" male at boths
ends.
K Check Valve 1" female, prevents
water backflow and pump running
dry.
L Thread Sealing Tape, 12 m roll.
1213
9. Repairs
10. Environmental Protection
11. Available Accessories
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metabo HWW 5500-20 M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metabo HWW 5500-20 M in the language / languages: English, German, Dutch, Danish, French, Swedish, Spanish, Finnish as an attachment in your email.

The manual is 5,85 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info