ENGLISH
1. Pump Overview.........................10
2. Please Read First!.....................11
3. Range of Application and
Pumping Media .........................11
4. Safety .........................................11
4.1 Specified Conditions of Use........11
4.2 General Safety Instructions ........11
5. Prior to Operation .....................12
5.1 Installation...................................12
5.2 Connecting the Suction Line.......12
5.3 Discharge Port............................12
5.4 Connection to a Pipe System .....12
5.5 Connection to AC Power ............12
5.6 Filling the pump and priming.......12
6. Operation...................................12
6.1 Commissioning ...........................13
7. Care and Maintenance..............13
7.1 Danger of Ffreezing....................13
7.2 Pump Dismounting and
Storing ........................................13
8. Trouble Shooting......................13
8.1 Locating the Fault .......................13
8.2 Adjusting the Pressure Switch ....13
8.3 Increasing the Precharge
Pressure .....................................14
9. Repairs.......................................14
10. Environmental Protection........14
11. Available Accessories.........14/49
12. Technical Specifications..........15
These operating instructions have been
written to make it easier for you, the
operator, to learn how to operate this
pump and to do so safely. These instruc-
tions should be used as follows:
Read these instructions before use.
When reading these instructions,
pay special attention to all safety
instructions.
These operating instructions are
intended for people with basic tech-
nical knowledge regarding the oper-
ation of a pump like this or similar
pumps. Inexperienced persons are
advised to seek competent advise
from an experienced person before
operating this pump.
Keep all documents supplied with
the pump for future reference.
Retain proof of purchase for possi-
ble warranty claims.
This pump must not be sold or lent
to someone else without being
accompanied by these operating
instructions and all other machine
documents supplied with the pump.
The manufacturer assumes no liabil-
ity for any damage resulting from the
non-observance of any operating or
safety instructions given in this man-
ual.
The information in these instructions is
denoted as under:
Danger!
Risk of personal injury or
damage to the environ-
ment.
Risk of electric shock!
Risk of personal injury
by electric shock.
Caution!
Risk of material damage
Note:
Additional information.
Numbers in illustrations (1, 2, 3, ...)
indicate component parts;
are consecutively numbered;
refer to the corresponding num-
bers in brackets (1), (2), (3) ... in
the neighbouring text.
Instructions to be carried out in
sequence are numbered.
Instructions which can be carried
out in any sequence are preceded
by a bullet (•).
Listing are preceded by a dash (–).
This pump is intended for pumping clear
water in domestic applications, such as
irrigation,
well, rain and service water pump-
ing,
draining of pools, garden ponds and
water tanks.
The max. permissible temperature of the
pumped medium is 35 °C.
4.1 Specified Conditions of
Use
This pump must not be used to supply
drinking water or for pumping foodstuff.
Explosive, flammable, aggressive fluids
or substances detrimental to health as
well as salt water must not be pumped.
This pump is not suitable for commercial
or industrial use.
Modification of the pump or use of parts
not approved by the manufacturer is not
permitted.
Any use other than the use specified
above may cause unforeseeable dan-
ger!
4.2 General Safety Instruc-
tions
Children, juveniles and persons not fam-
ilar with the instructions are not permit-
ted to operate the pump.
When used in swimming pools and gar-
den ponds and within their range of pro-
tection, the regulations of DIN VDE 0100
-702, -738 or applicable local regulation
must be observed.
When used as domestic water supply
any applicable local regulations pertain-
ing to water supply and waste water dis-
posal, plus DIN 1988 (where applicable)
have to be observed.
The following residual risks do principally
exist when operating pumps and pres-
sure vessels and can not be fully elimi-
nated – even by employing safety
devices.
A
Hazard generated by ambient
conditions!
x Do not expose to rain. Do not oper-
ate in damp or wet environment.
x Do not use the pump in hazardous
locations or near inflammable liquids
and gases!
B
Danger! Risk of electric shock!
x Do not direct water jet directly
against the pump or other electrical
parts! Risk of fatal electric shock!
x Do not touch the plug with wet
hands! To unplug always pull on the
plug, not the power cable.
x The earthed outlet or the plug con-
nection to an extension cable must
be located in an area safe against
flooding.
x Use only extension cables of suffi-
cient lead cross section (see
"Technical Specifications"). Com-
pletely unroll cable reels.
x Do not buckle, squeeze, drag or
drive over power cable and exten-
sion cables; protect from sharp
edges.
x Place extension cable so that it can
not get into the fluid to be pumped.
x Unplug:
prior to all servicing;
when persons are in the swim-
ming pool or garden pond.
A
Danger by pump failures!
x If you notice transport damage while
unpacking, notify your supplier
immediately. Do not operate the
pump!
Table of Contents
2. Please Read First!
3. Range of Application and
Pumping Media
4. Safety
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metabo HWW 4000-20G at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metabo HWW 4000-20G in the language / languages: English, German, Dutch, Danish, French, Spanish as an attachment in your email.

The manual is 0,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info