9
Pump clogged or defective.
- Disassemble and clean pump. Clean diffuser,
replace if necessary. Clean impeller, replace
if necessary. See section 11.
9.2 Pump not drawing in correctly or run-
ning very loudly:
Insufficient water.
- Ensure there is a sufficient water supply.
Pump not sufficiently filled with water.
- See section 6.7.
Suction line leaking.
- Seal suction line, tighten screw-couplings.
Suction height too high.
- Observe maximum suction height.
- Insert check valve, fill suction line with water.
Intake filter (accessories) obstructed.
- Clean, replace if necessary.
Check valve (accessories) blocked.
- Clean, replace if necessary.
Water discharge between motor and pump,
shaft seal leaking. (Minor discharge of water
(max. approx. 30 drops per day) is normal with
the use of shaft seals).
- Replace shaft seal. See section 11.
Pump clogged or defective.
- See section 9.1.
9.3 Pressure too low or pump runs continu-
ously:
Suction line leaking or suction height too high.
- See section 9.2.
Pump clogged or defective.
- See section 9.1.
HWW...: Pressure switch incorrectly adjusted.
- Read off switch-on and switch-off pressure at
the pressure gauge (3) and check values (see
section 13 Technical Specifications). If an
adaptation is necessary, please contact
Metabo Customer Service. See section 11.
HWW...: Pump starts up even after removal of
small volume of water (approx. 0.5 l).
- Check whether the pilot pressure in the pres-
sure vessel is too low. Increase pressure if
necessary. See section 9.4.
HWW...: Water is running out of the air valve.
- Rubber bellows in pressure vessel leaking,
replace it. See section 11.
9.4 Increasing pilot pressure (only HWW...)
If – in the course of time – the pump starts up even
after the removal of a small volume of water
(approx. 0.5 l), the pilot pressure in the vessel must
be restored.
Note:
The pilot pressure cannot be read off at the
pressure gauge (3).
1. Unplug mains cable.
2. Open the discharge line (open water tap or
spray nozzle), allow water to drain off
completely.
3. Unscrew plastic cap on front face of pressure
vessel; the air valve is located behind it.
4. Mount air pump or compressor hose with a
"tyre valve" connection and pressure gauge on
the air valve.
5. Pump up to the specified pilot pressure (see
section 13. Technical Specifications).
6. Connect device again and check operation.
f
Use only genuine Metabo accessories.
Use only accessories that fulfil the requirements
and specifications listed in these operating instruc-
tions.
For a complete range of accessories, see
www.metabo.com or the catalogue.
Danger! Repairs to this device must be
carried out by qualified electricians only!
If you have Metabo devices that require repairs,
please contact your Metabo service centre. For
addresses see www.metabo.com.
For shipment: drain pump and vessel completely
(see section 8.3).
You can download spare parts lists from
www.metabo.com.
Observe national regulations on environmentally
compatible disposal and on the recycling of
disused machines, packaging and accessories.
Only for EU countries: Never dispose of
power tools in your household waste! In
accordance with European Guideline 2002/
96/EC on used electronic and electric equipment
and its implementation in national legal systems,
used power tools must be collected separately and
handed in for environmentally compatible recy-
cling.
Explanatory notes on the specifications on page 3.
Changes due to technological progress reserved.
The pump characteristic curve (diagram on page
3) shows the conveying capacity that can be
reached depending on the conveying height
(suction height 0.5 m and 1" suction hose).
U =Mains voltage
f=Frequency
P
1
=Rated power
I =Rated current
C=Operating condenser
n =Rated speed
F
V,max
=max. conveying capacity
F
h,max
=max. conveying height
F
p,max
=max. conveying pressure
p
1
=Pressure switch: switch-on pressure
p
2
=Pressure switch: switch-off pressure
S
h,max
=max. suction height
S
temp
=max. supply temperature
T
temp
=Ambient temperature
S
1
=Splash protection class
S
2
=Protection class
S
3
=Insulation class
M
P
=Pump housing material
G=Grey cast iron
M
R
=Pump shaft material
M
W
=Pump impeller material
D
s
=Suction connection female thread
D
p
=Pressure connection female thread
T
V
=Pressure vessel volume
T
p,max
=max. vessel pressure
T
p,1
=Vessel pilot pressure
A =Dimensions:
Length x Width x Height
m =Weight (with mains cable)
~ Alternating current
The technical specifications quoted are subject to
tolerances (in compliance with the relevant valid
standards).
Emission values
Using these values, you can estimate the
emissions from this power tool and compare these
with the values emitted by other power tools. The
actual values may be higher or lower, depending
on the particular application and the condition of
the tool or power tool. In estimating the values, you
should also include work breaks and periods of low
use. Based on the estimated emission values,
specify protective measures for the user - for
example, any organisational steps that must be put
in place.
Typical A-effective perceived sound levels:
:
L
pA
=Sound pressure level
L
WA
=Acoustic power level
K
pA
, K
WA
= Uncertainty
L
WA(G)
=Guaranteed acoustic power level as per
2000/14/EC
Wear ear protectors!
10. Accessories
11. Repairs
12. Environmental Protection
13. Technical specifications
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metabo HWW 3300-25 G at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metabo HWW 3300-25 G in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 6,93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info