658505
9
Zoom out
Zoom in
Previous page
1/66
Next page
9
ENGLISH
3.3 Safety devices
Safety valve
The spring safety valve (10) is incorpo-
rated into the pressure switch unit. The
safety valve opens if the max. permissi-
ble pressure is exceeded.
4.1 Prior to initial operation
Wheel installation
1. Install wheels as illustrated.
2. Place starlocks on the wheels so
that the starlock's (12) clips are posi-
tioned exactly opposite the receiving
grooves of the wheels
(11) Then
push the starlocks onto the wheels.
4.2 Mains connection
B
Danger! High voltage
Operate machine in dry envi-
ronment only.
Operate machine only on a power
source complying with the following
requirements:
outlets properly installed, earthed
and tested;
fuse protection in accordance
with the Technical Specifications.
Position power cable so it does not
interfere with the work and is not
damaged.
Always check to see that the machine
is switched OFF before plugging in.
Protect power cable from heat,
aggressive liquids and sharp edges.
Use only extension cables with suffi-
cient lead cross section (see "Techni-
cal Specifications").
Do not stop the compressor by
unplugging, but switch OFF using the
switch.
Unplug after use.
4.3 Generating compressed
air
1. Start compressor (13) and wait until
the max. tank pressure is reached
(compressor shuts off). The tank
pressure is indicated by the tank
pressure gauge
(14).
2. Set pressure regulator (15) to
required working pressure.
A
Caution!
The regulated pressure may
not be set higher than the max. wor
-
king pressure of the connected air
tools!
3. Connect air hose to compressed air
outlet (16).
4. Connect air tool.
You are now ready to work with the
air tool.
5. Switch the compressor OFF, if you
do not continue working immediately
afterwards. Unplug after switching
OFF.
A
Danger!
Prior to all servicing:
Switch Off.
Unplug.
Wait until the compressor has
come to a complete stop.
Ensure the compressor and all air
tools and accessories connected
to it are relieved from pressure.
After all servicing:
Check to see that all safety
devices are operational.
Make sure that no tools or other
parts remain on or in the
machine.
Repair and maintenance work other
than described in this section must
only be carried out by qualified speci
-
alists.
5.1 Periodic maintenance
Prior to each use
Check air hoses for damage,
replace if necessary.
Check all screwed connections for
tightness, tighten if necessary.
Check power supply cable for dam-
age, if necessary have replaced by
a qualified electrician.
Every 50 operating hours
Check air intake filter , clean if nec-
essary (17).
Drain condensate (18).
Every 250 operating hours
Replace air filter element.
5.2 Machine storage
1. Switch unit OFF and unplug.
2. Release pressure from tank and all
connected air tools.
3. Store machine in such way that it
cannot be started by unauthorized
persons.
A
Caution!
Do not store machine unpro-
tected outdoors or in damp environ-
ment.
Do not lay machine on its side for
transportation or storing.
A
Danger!
Prior to all servicing:
Switch Off.
Unplug.
Wait until the compressor has
come to a complete stop.
Ensure the compressor and all air
tools and accessories connected
to it are relieved from pressure.
4. Operation
10
11
12
5. Care and Maintenance
15
14
13
16
6. Trouble Shooting
17
18
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metabo Basic 240 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metabo Basic 240 in the language / languages: All languages as an attachment in your email.

The manual is 2,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info