- A range of accessories may be fitted onto the threaded connections of the pump.
- The filter caps delivered are sufficient as suction protection in clear water.
- In order to prevent blocking the fountain nozzles, it may be necessary to use the filter sponge and filter
basket supplied in the case of „MP“ pumps.
- TIP! filter sponge and filter basket for operation with fountain nozzles are also available as accessories
with item number 168 / 009074.
Non submersible use (see fig. 3 + 4)
The pump can be used in a nonsubmerged type application.
- Position the pump below the water level, at the side of the pond so that the water can be fed to the pump
(not self-priming).
- Remove the filter cover (1) (see fig. 5).
- Connect suction hose (S) and pressure hose (D) to the pump. Connection should be waterproof.
- Fill suction hose and pump with water before switching-on.
- TIP! To prevent the pump becoming clogged, provide the suction hose with a prefilter
Art.-No. 168 / 009051 covered in our range of accessories.
Overload protection
The built-in thermal overload trip prevents the pump from being overheated.
The pump must cool down. When cool, the pump will start automatically again.
Check the following operating conditions:
- Is there a sufficient water supply?
- Has the filter become clogged?
- Has dirt entered the pump housing (Follow the cleaning instructions below)?
- Have hoses or jets become clogged?
- Has the pump cooled down?
As soon as you have solved the problems, you can start the pump again.
Dismantling / Assembly (see fig. 5 - 7)
1. Follow the safety measures. Disconnect the pump!
2. Press the filter cover (1) from on top and take it out of the pump.
3. Loosen the 4 screws (9).
4. Unclip pump housing (6) from motor housing (4).
5. Remove rotor assembly (8) from motor housing (4).
Pay attention to the O-ring (6) in the motor housing (4).
6. Clean all parts using clear water and soft sponge.
7. Mounting:
- Press the O-ring (7) onto the groove in the motor housing (4).
- Push the rotor assembly (8) onto the motor housing (4) with precaution and turn the bearing cap so
that the two holes fit on the pins in the motor housing (4).
- Make sure the rotor assembly is free and will turn.
- Check the position of the O-ring (6) in the motor housing (4).
- Plug the pump housing (6) in the motor housing (4) and tighten the 4 screws (9) uniformly.
- Screw the filter basket (10), filter sponge (11) (only supplied with „MP“ pumps) onto the pump
housing (6).
- Press the filter cap (1) into the motor housing (4)
Maintenance
In order to prolong the service life of your pump and to keep it in good operating condition, it is
recommended to carry out maintenance and cleanup regularly.
This can be done by everyone, quickly and easily. See „Dismantling / Assembly“
Servicing intervals
- In the beginning check performance of your pump every day. If necessary, clean the filters.
- Since servicing intervals (complete cleanup) will vary depending on pond pollution, repeat the periodic
service to your pump in accordance with the requirements given.
Should you determine that there are damaged or worn parts, do replace them. See „Spare parts“
Important! When used in calcareous water, the rotor assembly (8) and the stainless steel split tube
in the motor housing (4) should be cleaned at regular intervals.
Winter / Pump care
Protect your pump from freezing-in!
Take the pump out of your pond in autumn.
Clean the pump completely following the outlined instructions.
During the winter months store the pump in a tank filled with water to prevent the bearings from drying out.
Store the tank in a frost-resistant room.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Messner M 26000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Messner M 26000 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 1,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info