Table 1: Declaration - electromagnetic emissions
Guidanceandmanufacturer’sdeclaration-electromagnetic
emissions
The models WL1 and WL3 are intended for use in the
electromagneticenvironmentspeciedbelow.Thecustomeror
the user should assure that it is used in such an environment.
Emissions
test
Compli-
ance
Electromagnetic environment -
guidance
RF
emissions
CISPR11
Group 1
The models WL1 and WL3
use RF energy only for its
internal function. Therefore,
its RF emissions are very low
and are not likely to cause any
interference in nearby electronic
equipment.
RF
emissions
CISPR11
ClassB
The models WL1 and WL3
are suitable for used in
domestic establishment and
in establishment directly
connected to a low voltage
power supply network which
supplies buildings used for
domestic purposes.
Harmonic
emissions
lEC61000-
3-2
ClassC
Voltage
uctuations
/icker
emissions
lEC61000-
3-3
Not
applicable
TechnicalDescriptionConcerningElectromagnetic
Immunity
Table 2: Guidance & Declaration - electromagnetic
immunity
Guidance&Declaration—electromagneticimmunity
The models WL1 and WL3 are intended for use in the
electromagneticenvironmentspeciedbelow.Thecustomeror
the user should assure that It is used in such an environment.
Immunity test
IEC
60601
test level
Complia-
nce level
Electromagnetic
environment -
guidance
Electros-
tatic
discharge
(ESD)
lEC61000-
4-2
±6 kV
contact
±8 kV air
±6 kV
contact
±8 kV air
Floors should be
wood, concrete or
ceramictile.Ifoors
are covered with
synthetic material,
the relative humidity
should be at least
30 %.
Electrical fast
transient/
burst
IEC61000-
4-4
±2kV for
power
supply
lines
±1 kV for
Input/
output
lines
±2kV for
power
supply
lines
Mainspowerquality
should be that of a
typical commercial or
hospital environment.
Surge
lEC61000-
4-5
±1 kV
line to
line
±2 kV
line to
earth
±2 kV line
to earth
Mainspowerquality
should be that of a
typical commercial or
hospital environment.
Voltage
dips, short
interruptions
and voltage
variations on
power supply
input lines
IEC61000-
4-11.
<5%U
T
(>95%
dip in
U
T
.)
for0.5
cycle
40 % U
T
(60% dip
in U
T
)
for5
cycles
70% U
T
(30% dip
in U
T
)
for25
cycles
<5%U
T
(>95%
dip in
U
T
)
for5sec
<5%U
T
(>95%dip
in U
T
.)
for0.5
cycle
40 % U
T
(60% dip
in U
T
)
for5
cycles
70% U
T
(30% dip
in U
T
)
for25
cycles
<5%U
T
(>95%dip
in U
T
)
for5sec
Mainspowerquality
should be that of a
typical commercial or
hospital environment.
If the users of
the models WL1
andWL3require
continued operation
during power mains
interruptions, it is
recommended that
the models WL1 and
WL3 be powered from
an uninterruptible
power supply or a
battery.
Power
frequency
(50/60Hz)
magnetic
eld
lEC61000-
4-8
3 A/m
Not
applica-
ble
Not applicable
NOTE U
T
is the a.c. mains voltage prior to application of
the test level.
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Melissa Foto therapie 16780006 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Melissa Foto therapie 16780006 in the language / languages: English, German, Danish, Polish, Swedish, Norwegian, Finnish as an attachment in your email.

The manual is 1,98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info