Velocity Factor
The velocity factor is used by the instrument to convert the measured time for a pulse to be reflected, into a distance. It is
displayed as a ratio of the speed of light (eg 0.66 = 66% of the speed of light).
If the exact length of cable is known and the reflection from the cable end is visible then an accurate velocity factor can be
determined:
Locate the reflection caused by the end of the known length of cable with the instrument set on the shortest possible
range to see the end of the cable.
Locate the start of this reflection as described in the Operation section of this manual.
Adjust the velocity factor until the correct cable length is shown.
Note the VF value for future reference.
The measurement of the distance to the fault can now be made with more confidence. The ability of the instrument to accurately
measure the distance to a cable feature relies on the velocity factor being correct. Any errors in the velocity factor are directly
related to distance measurement errors.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Megger TDR500-3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Megger TDR500-3 in the language / languages: English as an attachment in your email.

The manual is 2,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Megger TDR500-3

Megger TDR500-3 User Manual - German - 30 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info