778360
32
Zoom out
Zoom in
Previous page
1/317
Next page
Tubing Connector
If insulin, or any liquid, gets inside the tubing connector, it can temporarily block
the vents that allow the pump to properly prime the infusion set. This may result
in the delivery of too little or too much insulin, which can cause hypoglycemia or
hyperglycemia. To prevent liquid from getting inside the tubing connector, after
you ll the reservoir make sure you hold the insulin vial upright when you remove
the reservoir from the transfer guard. If you do not hold the insulin vial upright,
insulin can get on the top of the reservoir and could transfer liquid into the tubing
connector. If any liquid gets on the top of the reservoir or inside the tubing
connector when you change your infusion set, start over with a new reservoir and
infusion set. For instructions on setting up your reservoir, see Setting up the
reservoir, on page 66. For instructions on changing your infusion set, see Changing
your infusion set, on page 68.
Tubing
connector
Top of
reservoir
Transmitter
Keep the transmitter away from children. This product contains small parts and
may pose a choking hazard.
Sensor
While there is no evidence of an Enlite sensor breaking in a patients body, if you
suspect that sensor breakage has occurred do not attempt to remove the sensor
yourself. Contact your physician for assistance removing the sensor.
Exposure to magnetic elds and radiation
If you are going to have an X-ray, MRI, diathermy treatment, CT scan, or other type
of exposure to radiation, take o your pump, sensor, transmitter, meter and remote
control before entering a room containing any of these equipment. The magnetic
elds and radiation in the immediate vicinity of these devices can make them non-
functional or damage the part of the pump that regulates insulin delivery, possibly
14 Chapter 1
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Medtronic MiniMed 530G at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Medtronic MiniMed 530G in the language / languages: English as an attachment in your email.

The manual is 12.74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info