Read the instruction manual carefully before using this device, es-
pecially the safety instructions, and keep the instruction manual for
future use. Should you give this device to another person, it is vital
that you also pass on these instructions for use.
GB Safety instructions
• The device must only be used for its intended purpose as described in the
instruction manual. Using the appliance for any other purpose invalidates the
warranty .
• Do not immerse the device in water or other uids and only use the device with
dry hands.
• Always carefully inspect the device for damage before use. Do not attempt to
use a defective unit.
• Do not dismantle or modify the device in any way .
• This appliance can be used by children aged from 8 years and above and per-
sons with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved.
• Children shall not play with the appliance.
• Do not use this device near ammable or corrosive materials or liquids.
• Do not use this unit to supplement or replace medical treatment.
• Do not store this device in direct sunlight and store it only in dry and well-venti-
lated areas.
• If the supply cord of this appliance is damaged, it must only be replaced by the
manufacturer , its service agent or similarly qualied persons in order to avoid a
hazard.
• The rechargeable battery must not be disassembled, heated, incinerated or ex-
posed to water .
• During the use of this device no water or cream residues must come in contact
with the device as this may lead to defects.
• Before use, remove any jewellery (e.g. nacklaces, earrings etc.) and contact
lenses.
• This device must not be used on sensible parts of the skin (e.g. eyes, ears, neck
etc.) - risk of injuries!
• Do not use this device on parts of the skin, which have been altered by cosmetic
procedures (e.g. after cosmetic surgery).
• Do not use the device during pregnancy or existing heart deseases.
• If you should feel unwell during use, stop the use immediately .
• Cleaning and head exchanging must only be done when the device is switched
o.
• If the device has been fallen or other damages are present, do not use the de -
vice - contact the customer service!
• Do not charge the battery during the use!
• The device must not be used by patients with allergies, skin deseases, derma-
titis, swellings, eczema or other serious (skin-) injuries.
• Cleaning and user maintenance shall not be made by children without supervi-
sion.
Scope of supply
Please check rst of all that the device is complete and is not damaged in any
way . In case of doubt, do not use the it and contact your dealer or your service
centre.
The following parts are included:
• 1 medisana Pore cleanser PR A60
• 4 dierent heads
• 1 USB charging cable
• 1 Instruction manual
If you notice any transport damage during unpacking, please contact your dealer
without delay .
Charging the battery
Charge the battery for at least 1 hour before rst use.
Explanation of the charging indicator 3 :
Red, constant light: Charging in progress - please do not interrupt.
Green light: Battery is fully charged.
Charge the battery in accordance with the following guidelines
• Charge the battery only with the supplied charging cable.
• Do not use the device during charging!
• Charging the battery:
Connect the mini USB plug of the included charging cable to the charging
port 4 of the device and connect the other end to a suitable power source.
Use
By pressing the On-/O-button 2 once, the device will be switched on at the lo-
west level (level 1). Pressing the button twice activates the medium level (level 2)
and three presses activate the highest level (level 3). A fourth press on the button
switches the device o again.
The head 6 (big, round opening)
This head provides a strong suction for heavily contaminated pores. Keep mo-
ving slowly on the skin from bottom to top with activated device.
The head 7 (thick and round)
This head is mainly suitable for the exfoliation of the facial skin. Y ou should not
use this head more than twice a week.
The head 8 (elliptic, transparent)
This head is especially suitable for eignet sich insbesondere for wrinkle
smoothing, promoting skin elasticity and blood circulation.
The head 9 (small, round opening)
This head is designed for sensible skin. It features a less strong suction than the
head 6 , but is also suitable for pore cleaning.
General instructions for handling:
• The application should not be longer than 30 seconds maximum twice daily at
the same part of the skin.
• Hold the head with light pressure on the skin area only - do not apply force or
greater pressure!
• After application, the skin area may become a little red. This is completely
normal and disappears by itself after some time.
• After using the device, do not scrub the skin area with brushes or rags. Y ou
can, however , moisten the skin with a little moisturizer .
Cleaning and maintenance
• Before cleaning the unit, make sure it is switched o . Clean the unit with a soft,
dry cloth.
• The head may be cleaned separately e.g. with a cotton swab.
• Under no circumstances should you use aggressive detergents, strong brush -
es, solvents or alcohol, as they may damage the surface of the unit.
• When cleaning, never immerse the unit in water and make sure that no water
gets into the unit.
• Y ou should ideally store the device in its original packaging and keep it in a
clean, cool and dry place.
Disposal
This product must not be disposed of together with domestic waste.
All users are obliged to hand in all electrical or electronic devices,
regardless of whether or not they contain toxic substances, at a
municipal or commercial collection point so that they can be disposed
of in an environmentally acceptable manner . Consult your municipal authority or
your dealer for information about disposal.
T echnical specications
Name and model:
Battery:
Input:
Power consumption:
Application time:
V acuum suction:
Noise:
S iz e approx.:
Weight approx.:
Item number:
EAN number:
W ARNING
Please ensure that polythene packing is kept away from the reach
of children! Risk of suocation!
medisana Pore cleanser PR A60
Lithium-Ion, 3.7V , 400mAh (charging time approx. 1 h)
5V , 0.4A
4 watts
45 minutes
60-65 kPa, level 1: 63.8 kPa ± 10%, level 2 : 64.1 kPa
± 10% kPa, level 3: 64.5 kPa ± 10%
58.5 dB (in 1 m distance)
19.5 x 8.5 x 4.5 cm
170 g
99458
40 15588 99458 6
The current version of this instruction manual can be found under www .medisana.com
In accordance with our policy of continual product improvement, we reserve
the right to make technical and visual changes without notice.
DE/GB
GB Instruction manual
Pore cleanser PR A60
Device and controls
IMPORT ANT
Non-observance of these instructions
can result in serious injury or damage
to the device.
W ARNING
These warning notes must be observed
to prevent any injury to the user .
CAUTION
These notes must be observed to pre-
vent any damage to the device.
NOTE
These notes give you useful additional
information on the installation or opera-
tion.
Do not use the device in damp rooms
(e.g. when bathing or showering).
LOT number
Manufacturer
1 Position for exchangeable head
2 On-/O-button
3 Charging indicator
4 USB charging port
5 USB charging cable
6 Head (big, round opening)
7 Head (thick and round)
8 Head (elliptic, transparent)
9 Head (small, round opening)
W arranty and repair terms
Please contact your dealer or the service centre in case of a claim under the war-
ranty . If you have to return the unit, please enclose a copy of your receipt and
state what the defect is.
The following warranty terms apply:
1. The warranty period for medisana products is three years from date of
purchase. In case of a warranty claim, the date of purchase has to be proven
by means of the sales receipt or invoice.
2. Defects in material or workmanship will be removed free of charge within the
warranty period.
3. Repairs under warranty do not extend the warranty period either for the unit
or for the replacement parts.
4. The following is excluded under the warranty:
a. All damage which has arisen due to improper treatment, e.g. non-
observance of the user instructions.
b. All damage which is due to repairs or tampering by the customer or
unauthorised third parties.
c. Damage which has arisen during transport from the manufacturer to the
consumer or during transport to the service centre.
d. Accessories which are subject to normal wear and tear .
5. Liability for direct or indirect consequential losses caused by the unit are
excluded even if the damage to the unit is accepted as a warranty claim.
medisana GmbH
Jagenbergstr . 19
41468 NEUSS
GERMANY
1
2
3
4
5
6
7
8
9
Explanation of symbols