3 Operating / 4 Miscellaneous
GB
3.4 Faults and Fault Remedying
Device will not switch on (LED not illuminating): Plug in the plug; Check power circuit, socket and fuse.
No mist (LED lights up red): Fill water tank.
No mist although tank full: Move rotary knob to „High“; Place device on a level surface; Clean atomiser
and generator using provided brush and fill tank with clean water; Rinse device with clean water.
White deposits: Use clean water or at least 1/2 distilled water / 1/2 fresh tap water. If a fault cannot
be remedied using the described method, please contact your service centre.
4 Miscellaneous
4.1 Cleaning and maintenance
During everyday use it is advisable to give the device a thorough cleaning at least every three days.
Also clean device before and after long storage periods.
Before cleaning the device, make sure that it is turned off and the mains plug is removed from the
socket.
Remove the water tank from the device and empty it.
Clean the outside of the unit with a soft, damp cloth.
Please do not use any aggressive substances for cleaning, such as scouring cream or other detergents,
as these may damage the surfaces and reduce the atomisation effect.
You can rinse out the water tank with hot water (>65 °C) or an alcohol of at least 75 % vol. The ato-
miser chamber should be cleaned using an alcoholsoaked cloth and cotton bud. Take care to ensure
that no water gets inside the humidifier.
The ultrasound generator is the most sensitive component in the device. It is important for it to be
kept clean and handled with care. Please use the pro-vided brush to remove deposits and dirt particles
from the outlets. Never clean the ultrasound generator using metal objects.
If you do not intend to use the unit for an extended period of time, empty any remaining water from
the tank and dry off the unit.
When cleaning the unit, rinse the filter in clean water. If you are not using the unit for an extended
period, store the filter separately so that it can dry.
Store the unit in a cool, dry place, preferably in its original packaging.
Remove cap from underside of the water tank and store separately to prevent sleeve gasket from
sticking.
4.2
Water filter
/ Descaling
Water filter
The humidifier AH 660 is equipped with a water filter. This filter assists in cleaning and demineralisation
of water. Depending on the hardness of the water used, the filter should be changed at least once
per month if the device is used daily.
Proceed as follows: Screw the lid off of the water tank and turn the filter out of the lid anti-clockwise.
Turn the new filter in the reverse direction back into the lid.
Descaling
When using hard water, or water with a high mineral content, the device must be regularly descaled.
Please use only citric acid for descaling (powder preparation from the chemist). (No liquid descaler!
No descaling tablets! No vinegar!).
- Empty out the device completely (tank and lower section).
Ensure that no liquid runs into the air outlet of the lower section.
- Place 4 tablespoons (approx.100g) of pure citric acid in the tank and fill up with 2000ml of water
at 60 °C. Screw the tank shut and gently shake until the citric acid powder has dissolved.
- Place the tank on the lower section. DO NOT SWITCH ON THE DEVICE!
- Allow the descaling solution to cool in the tank/device (at least 3 hours).
- Remove the tank from the device and, with a suitable brush (bottle brush or similar), scrub the
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Medisana AH 660 - 60067 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Medisana AH 660 - 60067 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Swedish, Spanish, Finnish as an attachment in your email.

The manual is 0,68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info