Malfunctions Cause Remedy
after sewing.
Needle is too thin to stitch the
cloth.
See page 14
Pattern selection dial I not
turned properly.
See page 22
Needle is not inserted correctly. See page 14
Needle is bent or dull.
Insert a new
needle.
Neither needle nor thread fit for
sewing.
See page 14
Machine skips stitches
Upper threading is incorrect. See page 18
Upper thread tension is too
tight.
See page 21
Threading is incorrect.
See pages 15
and 18
Sewing foot pressure is to high. See page 28
Fabric puckers or gathers
of seam
Stitches are too big to sew the
cloth.
Non-woven lining under the
cloth is required for stitching
very thin cloth.
Put a non-
woven lining
under the cloth.
Upper thread tension is too low. See page 21
Thread makes loops
The combination of needle size,
thread size and fabric is
incorrect, either too thick or too
thin.
See page 14
Fibres block the feed dog. See page 46
Feed dog is discharged. See page 27
Fabric does not feed
properly
Stitches are too small. See page 23
48


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Medion MD 11871 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Medion MD 11871 in the language / languages: English as an attachment in your email.

The manual is 2,18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info