491960
12
Zoom out
Zoom in
Previous page
1/37
Next page
Emergency Method (Resets Configuration to Default)
Disconnect the power jack at the rear of the Mede8er then plug it back
in - Now press the on/off button and hold it pressed for 10 seconds and then release.
After approximately 15 seconds the LED on the Mede8er with flash blue and you will get a progress bar on
your TV display (some TV's will not display this) wait until the Mede8er re boots itself +- 60 sec. Your Mede8er
is now updated.
FIRMWARE UPDATE
WIRELESS NETWORK SETUP (basic)
The Mede8er MED400X2 is only compatible with the Mede8er Wireless Dongle 802.11n
(Other brands will not work)
Refer to User Instructions supplied with the Mede8er dongle for detailed wireless connection setup.
Power Up and hold on/off button
for 10 seconds
Only use model MED10WFB WiFi Dongle as it is supplied together with the USB extension cable base.
WIRELESS NETWORK CONNECTION
Plug the MED10WFB into the USB extension base that
was supplied with your Mede8er. Plug the USB cable
into one of the USB host ports on the side of the
Mede8er. Extend the cable and try to place the base in
a position that is away from any metal object that could
effect the RF signal strength. The best placement for
the dongle will depend on your particular environment. In order to get the best placement you may need to
extend the length with an additional USB extension cable.
Note: The draft N standard prohibits using High Throughput with WEP or WPA2-PSK as the unicast cipher,
and your data rate will drop to 54 Mbps (802.11g) which is normal. Please try other encryption methods (WPA-
PSK), or choose to configure an unsecured profile.
The operating distance or range of your wireless connection can vary significantly based on the physical
placement of the Router and the WiFi Dongle.
For best results, place your Router:
* Near the center of the area in which your Mede8er will operate,
* In an elevated location such as a high shelf,
* Away from potential sources of interference, such as PCs, microwaves, and cordless phones,
Page11
Download the latest Mede8er Firmware from www.mede8erforum.com. UnZIP or UnRAR or join with HJ Split
and will find one file named install.img. Copy this file to the root directory of a Flash Drive. Plug the flash drive
into the Mede8er.
DO NOT REMOVE POWER DURING THE EMERGENCY RECOVERY PROCEDURE.
Setup Menu Update with Auto Configuration Restore
Open the Setup Menu and select the “Misc” tab. Now select USB upgrade option. After +- 5 sec the screen
will display the current Firmware Version and the New Firmware Version. You will have the option to select
“OK” or “Cancel”. Select “OK” and the Mede8er will reboot within +- 1 second and start the update process will
start in +- 10 seconds. During the update process the front facia Blue LED will flash and you will see the
version of the Firmware and the install progress bar on your TV screen. After the update is complete the
Mede8er will reboot with the new firmware installed.
If the Mede8er does not reboot within 5 seconds
(after pressing the "Enter" button) then press the
"Home" button to initiate
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mede8er MED400X2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mede8er MED400X2 in the language / languages: English as an attachment in your email.

The manual is 2,71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Mede8er MED400X2

Mede8er MED400X2 User Manual - Dutch - 33 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info