470208
45
Zoom out
Zoom in
Previous page
1/60
Next page
45
MAINTENANCE
Your ETX model telescope is a precision optical instrument designed to yield a
lifetime of rewarding observations. Given the care and respect due any precision
instrument, the telescope will rarely require factory servicing or maintenance. Use the
following guidelines:
1. Avoid cleaning the telescope’s optics: a little dust on the front surface of the
telescope’s correcting lens causes virtually no degradation of image quality and
should not be considered reason to clean the lens.
2. When absolutely necessary, remove dust from the front lens with gentle strokes of
a camel-hair brush or blow it off with an ear syringe (available at any pharmacy).
Do not use a commercial photographic lens cleaner.
3. You may remove organic materials (e.g., fingerprints) from the front lens with a
solution of 3 parts distilled water to 1 part isopropyl alcohol. A single drop of
biodegradable dishwashing soap may be added per pint of solution. Use soft, white
facial tissues and make short, gentle strokes. Change tissues often.
Caution: Do not use scented, colored or lotioned tissues or damage could
result to the optics.
4. In the very rare situation where cleaning the inside surface of the corrector lens
becomes necessary, unthread the lens cell located at the front of the main tube.
The entire correcting lens and secondary mirror system are mounted in this cell.
You may use the lens-cleaner solution described in step 3 to clean the inside
surface of the lens.
Caution: Do not touch the aluminized circular surface of the secondary
mirror with a finger, a tissue or any other object. This will almost certainly
scratch the mirror surface.
Note: When cleaning the inside surface of the correcting lens, leave the lens
mounted in its metal cell throughout the process. Do not remove the lens
from its metal housing or optical alignment of the lens will be lost,
necessitating a return of the telescope to the Meade factory.
5. If your ETX model is used outdoors on a humid night, telescope surfaces may
accumulate water condensation. While such condensation does not normally
cause any damage to the telescope, it is recommended that the entire telescope
be wiped down with a dry cloth before being packed away.
Do not, however, wipe
any of the optical surfaces. Rather, simply allow the telescope to sit for some time
in warm indoor air, so that the wet optical surfaces can dry unattended. In addition,
the dust cap should not be placed back on to the optical tube until the telescope is
thoroughly dry.
6. If your ETX model is not to be used for an extended period, perhaps for one month
or more, it is advisable to remove the eight AA-size batteries from inside the drive
base. Batteries left installed for prolonged periods may leak, causing damage to the
telescope’s electronic circuitry (see
HOW TO ASSEMBLE YOUR TELESCOPE AND TRI-
POD, page 12).
7. The super-gloss anodized finish of any ETX model’s deep-violet optical tube fades
if left in direct sunlight for prolonged periods.
8. Do not leave your ETX model outdoors on a warm day or inside a sealed car for an
extended period of time; excessive ambient temperatures can damage the
telescope’s internal lubrication and electronic circuitry.
9. A set of two (English-format) hex wrenches is provided with ETX models. These
wrenches are used as follows:
Small wrench (.05”): Use the small wrench to tighten the set-screws of
any knobs that may loosen (
e.g., the focus knob or flip-mirror control
knob).
Medium wrench (1/16”): This wrench is used to detach the viewfinder
bracket from the telescope’s rear cell.
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Meade ETX-105AT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Meade ETX-105AT in the language / languages: English as an attachment in your email.

The manual is 4,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info