The MeacoWall 53B/W, the MeacoWall 84B/W and the MeacoWall 108B/W dehumidifiers
use the new R32 refrigerant gas to comply with European Environmental Directives. R32
is kinder to the environment and is part of attempts to reduce global warming as it has a
low greenhouse effect (GWP).
When using the either the MeacoWall 53B/W, the MeacoWall 84B/W and the MeacoWall 108B/W
dehumidifier you must take into account the following:
This dehumidifier uses about 750 grams of R32 refrigerant in the 53L model, 1000 grams of
R32 refrigerant in the 84L mode and 1250 grams of R32 refrigerant in the 108L model, which
is flammable. Therefore, it is part of a sealed system and must only be serviced by a trained
Meaco engineer.
Do not use or store this dehumidifier in a room smaller than 4m² to prevent a fire or explosion
hazard if there is a leak of refrigerant and the gas comes into contact with an ignition source.
Do not use in a room with any continuous sources of ignition, for example open flames, gas
fires or hobs, cigarettes or any other sources of ignition.
If the dehumidifier is installed, operated or stored in a non-ventilated area, then the room must
be designed to prevent the accumulation of refrigerant leaks resulting in a risk of fire or
explosion due to ignition of the refrigerant caused by electric heaters, cookers, or other sources
of ignition.
R32 refrigerant gas is odourless.
Do not puncture either during the units working life or after. At the end of life dispose of following
local recycling regulations.
If there is any damage to the unit then do not use it and contact Meaco or your retailer.
As with all dehumidifiers, always keep upright and leave the dehumidifier standing upright for
3-4 hours before using it upon receipt.
Failure to comply with these instructions could result in fire, damage to property, serious
injury or potentially death.
Individuals who operate or work on the refrigerant circuit must have the appropriate certification issued
by a national accredited organisation that ensures competence in handling flammable refrigerants
according to a specific evaluation recognised by national associations in the industry and compliant
with the latest R32 guidance.
Servicing should only be carried out by a Meaco approved engineer using original Meaco parts to
prevent damage to the unit and potential injury to the engineer.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Meaco Wall 53 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Meaco Wall 53 in the language / languages: English as an attachment in your email.

The manual is 1.25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Meaco Wall 53

Meaco Wall 53 User Manual - German - 19 pages

Meaco Wall 53 User Manual - Dutch - 19 pages

Meaco Wall 53 User Manual - French - 19 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info