643529
11
Zoom out
Zoom in
Previous page
1/42
Next page
Chapter 2
INSTALLATION AND USE MANUAL
page 11
Theoretical notions for installation Technical service – MCZ Group S.p.A. all rights reserved - Reproduction prohibited
2.6. COWL
If underestimated, it is a severe impediment to correct "chimney
system" operations.
Flue pipe draught also depends on its cowl.
Therefore, if hand made, its four exhaust sections must correspond to
more than twice the internal section of the flue pipe.
Having to exceed the peak of the roof, the cowl will be
exposed to wind, therefore an industrial type is recommended.
The cowl must meet the following requisites:
It must have an internal section equal to that of the chimney.
It must have a useful output section not less that double that
of the internal section of the flue pipe.
It must be built to prevent rain, snow and any foreign objects
from getting into the flue pipe.
They must be installed to guarantee adequate smoke
dispersion and out of the reflux area where negative pressure
forms.
For paired flue pipes, the cowl for solid combustion
and the one for the upper floor must be at least 50cm
higher than the other to avoid pressure transfers
between paired flues.
The cowl must not have obstacles within 10 m such as
walls, roof slopes and trees. Otherwise, raise it at least
1 m over the obstacle and, in the event of other
nearby cowls, keep them at least 2 m away. In any
case, the cowl must exceed the peak of the roof by at
least 1m.
An industrial cowl,
with prefabricated
sections fitting
together, allows
optimal disposal of
the flue gases.
A traditional
handmade cowl.
The right exhaust
section must be at
least twice the
internal section of
the flue pipe, 2.5
times is ideal.
Steel cowl for flue pipe
with internal smoke
deflector cone.
1
m
t
0
,
5
m
t
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ Vivo 90 Wood at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ Vivo 90 Wood in the language / languages: English as an attachment in your email.

The manual is 2,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info