IMPORTANT!
The fireplace stove must be installed and
assembled by qualified personnel.
The fireplace stove must be connected to a flue
pipe or other vertical smoke stack that can
discharge smoke at the highest point of the
house.
The closed fireplace must be connected to a flue
pipe or internal or external vertical duct, in
accordance with the applicable standards in force.
Smoke is generated from burning wood and,
therefore, may dirty adjacent or nearby walls.
Before positioning the fireplace stove, you must
make a hole for the intake of external air.
2.3. CONNECTION TO THE EXTERNAL AIR INTAKE
The room where the stove is installed must have at least as much air as
requested by normal combustion of the equipment and by room
ventilation. This may take place through permanent apertures in the
room walls that lead directly outdoors or ventilated rooms according to
UNI 10683 REV.
For this purpose, drill a hole with minimum 360 cm² free section near
the fireplace stove (22 cm diameter or a 20x18cm rectangle), protected
by an indoor and outdoor grille.
The air intake must also:
directly communicate with the installation room
be protected by a grill, made of metallic anti-insect mesh or a
suitable protection as long as it does not reduce the minimum
section.
be installed so as to avoid obstruction
for ducts, up to 3.5 linear metres, increase the section by about
5% while increased by 15% for larger measurements.
Remember that the ventilation grills always have a cm
2
useful section on one side. When selecting the grill and hole
dimension, make sure the useful grill section is greater than
or equal to the section required by MCZ for product
operations.
IMPORTANT!
Air flow may also be obtained from a room adjacent
to the installation room as long as this flow is free
through permanent apertures that directly
communicate with the outdoors; avoid air outlets
connecting with heating units, garages, kitchens or
bathrooms.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ Vivo 90 Wood at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ Vivo 90 Wood in the language / languages: English as an attachment in your email.

The manual is 2,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info