13-PROBLEMS/CAUSES/SOLUTIONS
Technical Dept. - All rights reserved - Reproduction is prohibited
ANOMALY POSSIBLE CAUSES SOLUTIONS
The product works for a few minutes
and then switches o.
Start-up phase is not completed. Repeat start-up.
Temporary power cut. Wait for the automatic restart.
Clogged smoke duct. Clean the smoke duct.
Faulty or malfunctioning temperature
probes.
Check and replace the probes.
Faulty spark plug. Check the spark plug and replace it, if
necessary.
Pellets accumulate in the brazier, the
glass of the door gets dirty and the
ame is weak.
Insucient combustion air. Make sure there is an air inlet in the room
and it is not clogged. Check that the
combustion air lter on the Ø 5 cm air inlet
pipe is not clogged. Clean the brazier and
check that all the holes are clear. Perform
a general cleaning of the combustion
chamber and the smoke duct. Check the
state of the door gaskets.
Damp or unsuitable pellets. Change the type of pellets.
Faulty smoke evacuation motor. Check the motor and replace it, if necessary.
The smoke evacuation motor does
not work.
The product is not powered. Check the mains current and the
protection fuse.
The motor is faulty. Check the motor and capacitor and replace
them, if necessary.
The electronic board is faulty. Replace the electronic board.
The control panel is faulty. Replace the control panel.
The convection air fan never stops. Faulty or malfunctioning temperature
control probe.
Check the probe and replace it, if necessary.
Faulty fan. Check the fan and replace it, if necessary.
The remote control does not work. The remote control battery is at. Replace the batteries.
Faulty remote control. Replace the remote control.
55


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ Vivo 80 Pellet COMFORT AIR at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ Vivo 80 Pellet COMFORT AIR in the language / languages: English as an attachment in your email.

The manual is 4,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of MCZ Vivo 80 Pellet COMFORT AIR

MCZ Vivo 80 Pellet COMFORT AIR Usermanual and installation guide - French - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info