10-SAFETY DEVICES AND ALARMS
ALARM ALERTS
If an operating anomaly occurs, the product enters the shutdown phase due to an alarm and informs the user regarding the type of fault
by means of a 3 digit code that remains displayed on the emergency panel.
The alarm is indicated permanently by the relative 3 digit code, a ashing red LED that lights up on the emergency panel and an
intermittent buzzer for the rst 10 minutes. Read the instructions in the following 2 paragraphs to cancel the alarm status and restore
the normal operating mode of the stove. The following table describes the possible alarms indicated by the product, associated to the
respective code that appears on the emergency panel and helpful tips to resolve the problem.
DISPLAY
MESSAGE
TYPE OF PROBLEM SOLUTION
A01
The ame does not light Check the level of pellets in the tank.
Check that the brazier is correctly positioned in its seat
and has no incrustation or unburned material.
Make sure the ignition plug warms up.
Thoroughly empty and clean the brazier before
restarting.
A02
The re goes o abnormally. Due to the hopper being empty (no fuel).
A03
The pellet hopper temperature exceeds the
intended safety threshold.
The structure overheats due to reduced heat
dissipation.
The structure is too hot because the product has been
used for too long at the maximum power or due to poor
ventilation or because the air fans are faulty. When
the product is suciently cold, press button B on the
control panel or OFF on the remote control to delete
alarm A03. Once the alarm is deleted, the appliance
can be switched on.
A04
The temperature of the exhaust smoke has
exceeded the preset safety limits.
The appliance switches o automatically. Let the
product cool down for a few minutes and then switch
it on again. Check the smoke expulsion and the type of
pellets used.
A05
Clogged ue-wind-door open. Check the smoke duct and make sure the door is closed.
A06
The smoke extractor fails to guarantee sucient
primary air, required for a correct combustion.
Insucient draught or clogged brazier.
Verify whether the brazier is clogged and clean it, if
necessary.
Check and if necessary clean the smoke duct and air
inlet.
A08
Faulty smoke fan. Verify whether the smoke fan compartment is clean,
and particularly if it is blocked by dirt. If this does not
suce, the smoke fan is faulty. Contact an authorised
service centre to have it replaced.
A09
The smoke probe is faulty and does not detect
the exhaust smoke temperature correctly.
Contact an authorised service centre to have the
component replaced.
44


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ Vivo 80 Pellet COMFORT AIR at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ Vivo 80 Pellet COMFORT AIR in the language / languages: English as an attachment in your email.

The manual is 4,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of MCZ Vivo 80 Pellet COMFORT AIR

MCZ Vivo 80 Pellet COMFORT AIR Usermanual and installation guide - French - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info