10-HYDRAULIC CONNECTION
Technical Dept. - All rights reserved - Reproduction prohibited
CONNECTING THE SYSTEM
Make the connections to the corresponding ttings shown in the diagram on the previous page. Make sure the pipes are not placed under
tension or undersized.
IT IS STRONGLY RECOMMENDED TO WASH THE ENTIRE SYSTEM BEFORE CONNECTING THE STOVE IN ORDER TO GET RID
OF RESIDUES AND DEPOSITS.
Upstream from the stove, always install shutters so as to disconnect it from the plumbing system should it be
necessary to move it, or when it requires routine and/or special maintenance. Connect the stove using hoses so that
the stove is not too strictly connected to the system, and to allow slight movements.
The pressure discharge valve (C) is always connected to a water drain pipe. The pipe must be adequate to support the
water’s high temperature and pressure.
CLEANING THE SYSTEM
It is mandatory for the connections to be easy to disconnect by way of unions with rotating connection.
Install suitable shutters to cut o the tubes from the heating system. Assembling the safety valve on the system is compulsory.
In order to protect the heating system from damage caused by corrosion, incrustation or deposit build-up, it is important to clean the
appliance before installation, using suitable products, in compliance with Standard UNI 8065 (water treatment of thermal plants for civil
use).
The use of FERNOX PROTECTOR F1 (available at our authorised centres) product is recommended, this provides long term protection
against corrosion and calcium build-up for heating systems. It prevents the corrosion of the metal parts of the appliance, i.e. the ferrous
metals, copper and copper and aluminium alloys. It also reduces the noise produced by the boiler. Refer to the instructions on the product.
Cleaning should be performed by a qualied technician.
We also recommend the use of FERNOX CLEANER F3 and LEAK SEALER F4, always available from our authorised distribution centres.
FERNOX F3 is a neutral product for rapid and ecient cleaning of heating appliances. It has been designed to eliminate residues, oily
deposits and incrustations from existing appliances of all ages. It can help restore the heating eciency of the boiler and reduce the noise
it generates.
FERNOX F4 is intended to be used with all heating appliances to seal micro fractures that cause small and inaccessible leaks.
FILLING THE SYSTEM
To ll the system, the stove can be equipped with an end piece (optional) with a non-return valve (D) for manual lling of the heating
system (if the optional is not installed, the lling tap on the main boiler will be used). During this operation, any air in the system is
released from the automatic vent valve located under the top.
To ensure the valve vents, it is advisable to loosen the grey cap one turn and leave the red cap blocked (see gure). Set the lling pressure
of the system WHEN COLD to 1 bar (100 kPa). During operation, if the system pressure drops (due to evaporation of dissolved gases in the
water) to values lower than the minimum indicated above, the user must use the lling tap to bring the pressure back up to its normal
pressure.
To ensure correct stove operation, the maximum pressure in the system WHEN HOT must not exceed 1.5 bar (150 kPa).
Fit the system with a 2 bar safety valve connected to an accessible outlet.
To monitor the system pressure, the terminal (optional) is equipped with a manometer (M).
Upon completion of this operation, always close the tap.
It is normal to hear noises and gurgling until all the air in the system is released.
63


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ SUITE Hydromatic 24 M2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ SUITE Hydromatic 24 M2 in the language / languages: English as an attachment in your email.

The manual is 8.43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of MCZ SUITE Hydromatic 24 M2

MCZ SUITE Hydromatic 24 M2 User Manual - English - 68 pages

MCZ SUITE Hydromatic 24 M2 User Manual - German - 68 pages

MCZ SUITE Hydromatic 24 M2 Installation Guide - German - 68 pages

MCZ SUITE Hydromatic 24 M2 User Manual - Dutch - 68 pages

MCZ SUITE Hydromatic 24 M2 Installation Guide - Dutch - 76 pages

MCZ SUITE Hydromatic 24 M2 User Manual - French - 68 pages

MCZ SUITE Hydromatic 24 M2 Installation Guide - French - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info